Quick start
PCD2.H31x
Page 6-12
SAIA-Burgess Electronics Ltd.
(2H3-06-E.DOC)
26/762 E2
LD
R 1000
4.0
; Mechanical factor
LD
R 1001
8000
; Initial absolute speed
LD
R 1002
10000
; Initial absolute acceleration
CFB
Init
; Initialization FB
K 1
;
Module number
250
;
Proportional factor (regulator)
0
;
Integrative factor (regulator)
0
;
Derivative factor (regulator)
4000
;
Integrative limit value
5
;
Derivative term sampling interval
500
;
Position tolerance
0
;
Behaviour in case of position error
R 1000
;
Mechanical factor register
R 1001
;
Initial velocity register
R 1002
;
Initial acceleration register
EST
;10
For example, if initial absolute acceleration is to be increased from
10 000 to 30 000, absolute program line 19 should be processed:
<Write> <Program> <19> <CR> <30000> <CR> <Esc>
When motion is resting: Switch PCD input I 1 on and off. This means that
the modified parameters are adopted. By switching on I 0 the new be-
haviour can be tried out, etc.
Содержание PCD2.H310
Страница 8: ...Contents PCD2 H31x Page 4 SAIA Burgess Electronics Ltd 2H3 00 E DOC 26 762 E2 Notes...
Страница 18: ...Introduction PCD2 H31x Page 1 8 SAIA Burgess Electronics Ltd 2H3 01 E DOC 26 762 E2 Notes...
Страница 28: ...Terminals PCD2 H31x Page 4 4 SAIA Burgess Electronics Ltd 2H3 04 E DOC 26 762 E2 Notes...
Страница 52: ...Quick start PCD2 H31x Page 6 14 SAIA Burgess Electronics Ltd 2H3 06 E DOC 26 762 E2 Notes...
Страница 66: ...Error handling and diagnosis PCD2 H31x Page 8 4 SAIA Burgess Electronics Ltd 2H3 08 E DOC 26 762 E2 Notes...
Страница 92: ...Commissioning tool PCD2 H31x Page 10 10 SAIA Burgess Electronics Ltd 2H3 10 E DOC 26 762 E2 Notes...
Страница 110: ...Application examples PCD2 H31x Page 12 16 SAIA Burgess Electronics Ltd 2H3 12 E DOC 26 762 E2 Notes...
Страница 152: ...Summary of all FBoxes PCD2 H31x Page B 2 SAIA Burgess Electronics Ltd 2H3 AB E DOC 26 762 E2 Notes...
Страница 154: ...SAIA Burgess Electronics Ltd Your suggestions...