Summary of software elements
PCD2.H31x
Page A-34
SAIA-Burgess Electronics Ltd.
(2H3-AA-E.DOC)
26/762 E2
LdBrkPtAbs
Instruction:
Load Break Point Absolute
[28]
Function description:
This instruction can be used to load an absolute breakpoint (signalling an
intermediate position). The absolute position always refers to the zero po-
sition.
If the breakpoint is reached, the 'fBrkPt_x' flag is set. However, this flag
only becomes active after FB 'RdStatRg' has been processed.
Description of input and output elements concerned:
Par.
Designation/function
Type
Format
Value
Comment
= 1
Module number
K
1 - 16
= 2
Instruction:
LdBrkPtAbs
= 3
PCD register with the
load value
R
integer
31 bit
-2
30
.. +(2
30
- 1)
fBrkPt_x
Flag 'Breakpoint'
F
This flag is reset
with instructions
'StartMot' or
'ResStatRg' .
Exec
Function Block
Index modified: no
Processing time: 4.7 ms
= 2
LdBrkPtAbs
= 1
Module number
= 3
Load value register
Содержание PCD2.H310
Страница 8: ...Contents PCD2 H31x Page 4 SAIA Burgess Electronics Ltd 2H3 00 E DOC 26 762 E2 Notes...
Страница 18: ...Introduction PCD2 H31x Page 1 8 SAIA Burgess Electronics Ltd 2H3 01 E DOC 26 762 E2 Notes...
Страница 28: ...Terminals PCD2 H31x Page 4 4 SAIA Burgess Electronics Ltd 2H3 04 E DOC 26 762 E2 Notes...
Страница 52: ...Quick start PCD2 H31x Page 6 14 SAIA Burgess Electronics Ltd 2H3 06 E DOC 26 762 E2 Notes...
Страница 66: ...Error handling and diagnosis PCD2 H31x Page 8 4 SAIA Burgess Electronics Ltd 2H3 08 E DOC 26 762 E2 Notes...
Страница 92: ...Commissioning tool PCD2 H31x Page 10 10 SAIA Burgess Electronics Ltd 2H3 10 E DOC 26 762 E2 Notes...
Страница 110: ...Application examples PCD2 H31x Page 12 16 SAIA Burgess Electronics Ltd 2H3 12 E DOC 26 762 E2 Notes...
Страница 152: ...Summary of all FBoxes PCD2 H31x Page B 2 SAIA Burgess Electronics Ltd 2H3 AB E DOC 26 762 E2 Notes...
Страница 154: ...SAIA Burgess Electronics Ltd Your suggestions...