Saia-Burgess
Controls Ltd.
Manual Modem PCDxx7 Serie│Doc. 26/793; Ed. E2│30.04.2005
Appendix
9
9-3
Appendix 2, Error Codes
9.2.2 Error return by the calling function
Status
Error
Description
3
0
An incoming call is actually processed
8
1
BUSY
16
1
No carrier
32
1
No DIAL TONE
10
1
Black listed (can’t process this number)
When a telephone number. is black listed this number automatically will be set free
again after 2 hours. A command for switch off black listing is not possible due to tel-
ecommunication restrictions.
9.2.3 Error return by the SMS function
Status
Error
Description
-1
(FFFFh)
1
TIME out, the SMS center didn’t answer to the SMS request in the 30
seconds.
1
1
Check sum error (internal)
2
1
Syntax Error
3
1
Operation not supported by the system
4
1
Operation not allowed at this moment
5
1
Call barring active
6
1
Recipient number invalid
7
1
Authentication failure
8
1
Legitimization code for all calls, failure
21
1
Standard text not valid
24
1
Message too long
9.2.4 Error return by the PAGER function
Status
Error
Description
-1
(FFFFh)
1
TIME out, the SMS center didn’t answer to the SMS request in the 30
seconds.
1
1
Check sum error (internal)
2
1
Syntax Error
3
1
Operation not supported by the system
4
1
Operation not allowed at this moment
5
1
Call barring active
6
1
Recipient number invalid
7
1
Authentication failure
8
1
Legitimization code for all calls, failure
21
1
Standard text not valid
24
1
Message too long
701
1