SAHARA DRY 80VF Скачать руководство пользователя страница 2

SECURITY

All the materials used were selected according to the UNI-CEI-EN specifications.
Thus these instruments, which received the CE marking, have reached a satisfactory degree of intrinsic safety, as long as the
users are qualified operators with knowledge of the rules for use and maintenance as exposed in this Manual, and safety devices
supplied are never misused.
There is even a ground point.
Acoustic pressure level is under 70dB.

I.P.D. ( Individual Protection Devices) - Minimum Req.'s

To avoid accidents, please follow these minimum requirements:
- Use protective gloves heat & steam-resistant.
- Use face-protecting mask to avoid possible scald injurie

Precautions

Ensure that:

- the unit is installed in a stable, horizontal position.
- the internal ventilation openings are not blocked.
- the instrument has a minimum space of 100 mm from the wall for a correct installation
- the working space has a temperature range from 5° to 40°C and the humidity range has to be between 30% and 80%.
- the instrument has to be connect to an circuit with ground (system) and with conformity to law.
- the instrument is correctly connect to a plug near to the unit, accessible and with identification sign.
- need to introduce item in the correct way inside the instrument to avoid fall down of them.
Avoid conditions of dust excess.

EC CONFORMITY

Units 8107.108-110-112, conform to EC directives directives:

EMC 2014/30/CE

,

LVD 2014/35/CE

,

MD 2006/42/CE

, the following harmonized

standards are in use EN 60204-1, EN 61000-6-1, EN 61000-6-3, EN 292.

A weighted sound pressure <70dB (A)
A weighted sound power < 85dB (A)

Rear sign:

WARRANTY

This unit is guaranteed against all defects due to faulty materials and workmanship, within 12 months from the date of purchase.
A use not conforming to what specified might be dangerous to the safety of the operator and may damage the unit.
In such circumstances the manufacturer is relieved of any liability and the warranty itself will decay.

Protecting the environment

Separate collection.This product must not be disposed of with normal household waste.
Should you find one day that your product needs replacement,or if it is of no further use to you,do not dispose of it
with household waste. Make this product available for separate collection.
Separate collection of used products and packaging allows materials to be recycled and used again.

Re-use of recycled materials helps prevent environmental pollution and reduces the demand for
raw materials.
Local regulations may provide for separate collection of electrical products from the
household,at municipal waste sites or by the retailer when you purchase a new product.

REPAIR

Repairs have not been attempted by anyone other than authorized repair distributors.
Do not try to repair the unit by yourself.

ATTENTION:

Dangerous voltage is present inside the unit.

Page 2

Sahara DRY, 07/.2021

S.N. 232217

SAHARA 80

230Vac/50Hz 1200W

Fuse: 6,3A

Содержание 80VF

Страница 1: ...SAHARA DRY 80VF 120VF 250VF FORCED VENTILATION BAKING OVEN with HUMIDITY CONTROL from 80 to 250 litre 40 280 C Instruction Manual Sahara DRY English...

Страница 2: ...onform to EC directives directives EMC 2014 30 CE LVD 2014 35 CE MD 2006 42 CE the following harmonized standards are in use EN 60204 1 EN 61000 6 1 EN 61000 6 3 EN 292 A weighted sound pressure 70dB...

Страница 3: ...372 477 522 Height mm 472 512 797 External Dimensions Width mm 796 836 956 Depth mm 570 680 730 Height mm 680 720 1025 Temperature Control P I D P I D P I D Humidity control ON OFF at T 100 C ON OFF...

Страница 4: ...ing function to change selected digit to modify value to confirm LED Air shows when the eletrovalve is ON and the dry air is insufflated LED shows the condition when ON OFF control is working relative...

Страница 5: ...rnal chamber when you want to reach temperatures of over 100 C FRESH AIR EXCHANGER Setting of air exchanger Air output 35mm diameter is placed on the rear side of the oven The opening and closing of t...

Страница 6: ...ressing to select digit and to modify the value Bypressing theparameterwillbememorized otherwiseifyouholddown for2secondsyouwillexit from the parameter setting function Example of setpoint at 195 C t...

Страница 7: ...you will exit from the parameter setting function At the end the display will show START TIME Press and insert the following parameters start month M start day d start hour h start minutes m Set param...

Страница 8: ...switched off in two ways 1 usingthemainswitchON OFF AtthenextswitchontheovenwillbeagaininProgmodeandthePIDwillworkimmediately 2 using the STOP mode Hold down for 2 seconds the display will show Prog P...

Страница 9: ...mpressed air The Eco mode is provided for a more rational use of compressed air in fact the low humidity is reached for cycles later and not in a direct way Deactivate the ON OFF humidity control Hold...

Страница 10: ...er exe inadirectoryofyourPCandrun it to be operative SETTING THE PIDLOGGER CONNECTION 1 Connect the Sahara oveb to the PC using the specific USB cable 2 Set the oven in Com On mode 3 Run PIDManager pu...

Страница 11: ...e end of memory is reached 21600 samples Every tyme SETPOINT COUNTDOWN and PROG mode are activated all previous data in memory are erased and overwritten The sample data are written inside non volatil...

Страница 12: ...button export to one of the 10 program memorized into the Sahara oven with Export button In every step of a program is possible to execute one of these 3 commands SET POINT the oven reach a setpoint t...

Страница 13: ...RYCONTROL ON OFF OPTIMIZATION for skilled personnel only To change the PID parameters hod down together and button for 6 seconds Insert the following parameter setpoint_low on the left and setpoint_hi...

Страница 14: ...all parts have reached a normal temperature Use a detergent with less than 5 of non ionic surfactant Lubricate the door inge and the closing system of the handle SPARE PARTS 8107 202 Pidlogger 8107 2...

Страница 15: ...PIDLogger DRYControl CONNECTIONS SaharaDRY 07 2021 Page15...

Страница 16: ...only Page16 SaharaDRY 07 2021 P I D control board EMI Filter Mains Input Fuses SSR 12V Yellow Lamp Alarm Reset Button Red Lamp Alarm Relay R R 1 R 2 Heating Resistance Fan Motor Transformer Over Tempe...

Отзывы: