80VF - 120VF - 250VF

FORCED VENTILATION

BAKING OVEN with HUMIDITY CONTROL

from 80 to 250 litre

40° - 280°C

Instruction Manual

Sahara DRY

English

Содержание 80VF

Страница 1: ...SAHARA DRY 80VF 120VF 250VF FORCED VENTILATION BAKING OVEN with HUMIDITY CONTROL from 80 to 250 litre 40 280 C Instruction Manual Sahara DRY English...

Страница 2: ...onform to EC directives directives EMC 2014 30 CE LVD 2014 35 CE MD 2006 42 CE the following harmonized standards are in use EN 60204 1 EN 61000 6 1 EN 61000 6 3 EN 292 A weighted sound pressure 70dB...

Страница 3: ...372 477 522 Height mm 472 512 797 External Dimensions Width mm 796 836 956 Depth mm 570 680 730 Height mm 680 720 1025 Temperature Control P I D P I D P I D Humidity control ON OFF at T 100 C ON OFF...

Страница 4: ...ing function to change selected digit to modify value to confirm LED Air shows when the eletrovalve is ON and the dry air is insufflated LED shows the condition when ON OFF control is working relative...

Страница 5: ...rnal chamber when you want to reach temperatures of over 100 C FRESH AIR EXCHANGER Setting of air exchanger Air output 35mm diameter is placed on the rear side of the oven The opening and closing of t...

Страница 6: ...ressing to select digit and to modify the value Bypressing theparameterwillbememorized otherwiseifyouholddown for2secondsyouwillexit from the parameter setting function Example of setpoint at 195 C t...

Страница 7: ...you will exit from the parameter setting function At the end the display will show START TIME Press and insert the following parameters start month M start day d start hour h start minutes m Set param...

Страница 8: ...switched off in two ways 1 usingthemainswitchON OFF AtthenextswitchontheovenwillbeagaininProgmodeandthePIDwillworkimmediately 2 using the STOP mode Hold down for 2 seconds the display will show Prog P...

Страница 9: ...mpressed air The Eco mode is provided for a more rational use of compressed air in fact the low humidity is reached for cycles later and not in a direct way Deactivate the ON OFF humidity control Hold...

Страница 10: ...er exe inadirectoryofyourPCandrun it to be operative SETTING THE PIDLOGGER CONNECTION 1 Connect the Sahara oveb to the PC using the specific USB cable 2 Set the oven in Com On mode 3 Run PIDManager pu...

Страница 11: ...e end of memory is reached 21600 samples Every tyme SETPOINT COUNTDOWN and PROG mode are activated all previous data in memory are erased and overwritten The sample data are written inside non volatil...

Страница 12: ...button export to one of the 10 program memorized into the Sahara oven with Export button In every step of a program is possible to execute one of these 3 commands SET POINT the oven reach a setpoint t...

Страница 13: ...RYCONTROL ON OFF OPTIMIZATION for skilled personnel only To change the PID parameters hod down together and button for 6 seconds Insert the following parameter setpoint_low on the left and setpoint_hi...

Страница 14: ...all parts have reached a normal temperature Use a detergent with less than 5 of non ionic surfactant Lubricate the door inge and the closing system of the handle SPARE PARTS 8107 202 Pidlogger 8107 2...

Страница 15: ...PIDLogger DRYControl CONNECTIONS SaharaDRY 07 2021 Page15...

Страница 16: ...only Page16 SaharaDRY 07 2021 P I D control board EMI Filter Mains Input Fuses SSR 12V Yellow Lamp Alarm Reset Button Red Lamp Alarm Relay R R 1 R 2 Heating Resistance Fan Motor Transformer Over Tempe...