ENGLISH
24/25
11. Troubleshooting
12. Circuit diagram
Problem
Cause Solution
Light tube
does not work
Light tube does
not turn off
Digital display
is blank or
is incomplete
Temperature and
time cannot be
adjusted
Light tube damaged
Lamp is not plugged in
Control silicon damaged
Control silicon damaged
Unplugged flat wire in circuit board
Digital display damaged
Switch imbalance
Circuit board damaged
Check light tube
Check the connections
Replace control silicon
Replace control silicon
Check flat wire
Replace digital display
Check the installation
of switch
Replace digital display
Aµ
Æ
K1
K1
K2
FAN
FAN
PCB
PCB
F
F
G1
G2
A
B
C
G1
G2
K2
K1
G1
G2
K2
K1
K2
Distance board
Distance sensor
AC 220V
A/C Contactor
Control Transformers
Control Transformers
Power Switch
Power Switch
G1
G2
DT6 Version
DT3 Version
K1
K2
G1
G2
K1
K2
G1
G2
Содержание DRY TECH DT 3