LAMP INSTALLATION 

 

• 

Loosen the knobs on the top lid and remove it. 

 

• 

Remove the lamp from the packing and carefully read the 

manufacturer’s instructions. 
 

• 

LAMP MSR 1200W: Insert the lamp into the ceramic socket. 

 

• 

LAMP HMI 1200: Loosen the two ring nuts at both end of the 

lamp. 
Place the lamp in its socket. Make sure the protuberance of the 
central bulb is facing downwards to avoid creating shadows in 
the projection. Tighten the two ring nuts on the lamp. 

 

• 

Replace the top lid and firmly tight the knobs. 

 

• 

Regulate the LAMP, with screws, if necessary. 

 
 

 
 
 
 
 
 
 
 
 
CONTROL UNIT 

 
 

TRACER FOLLOWSPOT 1200 comes with a control unit mounted on the adjustable bar and connected to the 
projector by means of a proper cable through 9 pin din connector. The TRACER CONTROL UNIT is powered at 
low voltage 12 Volts directly by the projector and it is able to control the fixture in all its functions. 
 
It is necessary to know that TRACER FOLLOWSPOT 1200 can be controlled by practically all types of controllers 
on the market that can execute the standard DMX 512 protocol. Controller-projector and projector-projector 
connections require a two-core screened cable provided with CANNON PLUGS AND SOCKETS. TRACER can 
use both 3 or 5 pin CANNON plugs and sockets because it comes with 3- and 5 pin CANNON SERIAL PORTS. 
The ground braid on the screened cable must be connected to just one end of the cable. The projector and cables 
must not be installed near overhead ducts for electrical cables or intense magnetic fields. 

 
 
PROJECTOR ADDRESS 

To make sure the projector functions properly , the dip-switches in the DMX ADDRESS AREA on the rear panel 
must be correctly configure. Keep in mind that each TRACER FOLLOWSPOT 1200 occupies 6 DMX channels. 
Each projector must be set separately on its own BASE CHANNEL (or STARTING CHANNEL) . The BASE 
CHANNEL assignment is obtained by summing the values for each switch in the DMX SECTION (for example, to 
set a projector on BASE CHANNEL #39, you must set dip-switches 32,4,2 and 1 to the ON position, because 
32+4+2+1= 39). In the Standard Operating Mode, this means the TRACER FOLLOWSPOT 1200 will receive 
signals on 6 channels following the BASE CHANNEL, BASE CHANNEL included (for example, if the projector is 
set on BASE CHANNEL #39, it will receive signals on channels #39, 40, 41, 42, 43 and 44) 

 
 

Содержание Tracer

Страница 1: ...I 1 1 12 2 20 0 00 0 0W W W i i in n nt t te e el l ll l li i ig g ge e en n nt t t d d di i is s sc c ch h ha a ar r rg g ge e e f f fo o ol l ll l lo o ow w ws s sp p po o ot t t USER S MANUAL relea...

Страница 2: ...ONNECTING THE PROJECTOR MAKE SURE THAT THE FREQUENCY AND THE VOLTAGE VALUES ARE SUITABLE AS SPECIFIED ON THE PROJECTOR FOR ANY DOUBT CONTACT YOUR SUPPLIER OR SEND AN E MAIL TO tech lamposrl it INDEX G...

Страница 3: ...per lid 3 Projector body 4 4 zoom system control 5 Lamp compartment 6 Bracket adjustment 7 Adjustable bracket 8 Cooling unit 9 Bar adjustment 10 TRACER control unit on board 11 TRACER console 12 Recli...

Страница 4: ...duct even in case of release The movement enabled by the support bracket is 45 compared to the assembly position of the bracket In order to recline the rear bar into the desired position it is necessa...

Страница 5: ...and 50 C HANDLING The projector with or without packing must be handled with care Lifting and handling must be carried out with special equipment Do not expose the projector with or without its packin...

Страница 6: ...he stability of the support elements when the projector is in working condition Do not install the projector where there are objects located at a distance of less than 20 centimetres from the cooling...

Страница 7: ...troller projector and projector projector connections require a two core screened cable provided with CANNON PLUGS AND SOCKETS TRACER can use both 3 or 5 pin CANNON plugs and sockets because it comes...

Страница 8: ...p lid and remove it Choose the pattern you want to replace and delicately press on it to extract it from a fastening clip Choose another gobo use standard M size gobos Insert the new pattern inside th...

Страница 9: ...et on OFF are controlled by the DMX CONTROLLED The dip switches of the control assignment section set on ON are controlled by the TRACER CONSOLE Do not remove the TRACER console When using the project...

Страница 10: ...TION ORANGE 50 99 39 2 58 4 FROST FILTER 100 149 58 8 78 0 CTB CORRECTION BLUE 150 199 78 4 100 0 FROST FILTER 200 255 CHANNEL 3 IRIS DIAPHRAGM percent values decimal values 0 2 4 CLOSED 0 6 2 7 100 I...

Страница 11: ...filter are controlled from here The colour temperature correction filter keys is used to set primary colours 5600 K warm colours 3200 K CTO or cold colours 6500 K CTB The FROST filter key is used to...

Страница 12: ...increases When the key is released intensity decreases As a result the operator can easily get exactly the right intensity for undetectable tracing Once the projector has been correctly positioned sim...

Страница 13: ...ed control means that the projectors are driver by any DMX console but allows the operator to decide the functions to use directly from the projector The projector can receive the signal from any DMX...

Страница 14: ...oom that let TRACER produce beams of different sizes The 4 OBJECTIVES system makes TRACER the most versatile projectors in its range From 10 to 50mt With projector ON in order to obtain the desired be...

Страница 15: ...s Remove knob A making sure the projector keeps its current position Insert a screw driver in the hold and turn clockwise or counter clockwise to optimise the horizontal position of the lamp compared...

Страница 16: ...smoky or dusty sections clean the projector more frequently CLEANING PROCEDURES 1 Open the top lid by unscrewing the knob and remove it from its seat 2 Use a low power comprised air to remove dust 3 U...

Страница 17: ...e power and clean the parts as explained in the cleaning paragraph In case of DMX control malfunctioning of the DMX cable Replace the cable and check the line before switching ON again the projector I...

Страница 18: ...of the client The warranty is not valid in the following cases 1 If the projector was used improperly or with negligence or if it was damaged and repaired and or modified to the point of jeopardizing...

Отзывы: