1-1) Remove the front cover

1)Mounting of Humistat

PUSH

② Push the cover-holding clutches and open the

① Loosen the fixing screw with a +(Plus)screwdriver

panel to the right.

less than axis diameter of 6 mm.

1-2) Mounting of humidistat

● Wall Mounting

50

50

2 6

1 7

2 7

Installation Dimension

Fixing screw(M3)

① Fix the base on the wall by tapping screws(M4),etc.

② Put the front cover to the base after wiring on the terminal.

① Close the front cover and tightened the fixing screw(M3) after wiring on the each terminal.

② Insert the panel fittings into the cutting-hole of the front cover, and mount the panel.

● Panel Mounting

-0.

+1

11

6

+1

-0.5

7 1

Panel Cutting Dimension

Panel Thickness

1 .6 ~ 3. 2 mm

Panel Thickness

1. 0 ~1 .6 m m

Fixing screw(M3)

!

CAUTION

of operators, or damage and malfunction of the device.

Failure in observing the following could result in injuries

●When insert the panel fittings,take care that you do not hurt hands.

Screw

Sensor holder

Sensor

Sensor

Heat Insulation Material

To put around

Pipe

Lead wire

of Sensor

Sillicon
or Putty

Fixing band

Fix with
tie-rap etc.

In case to use the sensor holder

Incase of pipe mounting

2)Installation of Temperature Sensor

●In case to use the sensor holder

・After mount the sensor holder by screws

or tapping screws (M3,M4), push the
temperature sensor into the sensor holder
and fix the sensor.

●In case of pipe mounting

・Fix the sensor by copper plate with

adequate isolation, and put around the
heat insulation material on the sensor.

2

●In case of insertion to pipe, bath

・Apply the bulb well as option.

●Lead wire extension of temperature sensor

・Use weather proof wires for extension out

of doors.

・Allowable extension distance is 100m or

less.(Lead wire : 0.5mm

or more)

proof / insulation treatment by taping.

・Make sure to connect and take the drip

Make sure to cut off the power before wiring,and start it after safety check.

the case with fixing screw.

Further,apply the power to the ULE after make sure to re-check the wiring and close

Wiring method

・Make sure to connect with M3.5 crimp terminal.
・When pull out lead wire,use a knock-out(back side and bottom of body)

according to the direction of pull out lead wire.

・2 lead wires of temperature sensor has no polarity.

output current,use an auxiliary relay suitable for the load.

the rating may result a contact welding. When the rush current exceed the allowable

Temp. sensor

●Wiring of Temperature Sensor.

In case of applying any voltage other
than the rated voltage,it may cause
damage, wrong working.

●Connect the power.

● When using an inductive load i.e.,compressor etc.,a rush current 3 to 10 times of

● Do not connect the power to the sensor terminals①②. It gives damage to ULE.

CAUTION

Circuit Breaker or Fuse

85VAC~264VAC

Switch

●Connect the load and the power for load.

!

CAUTION

of operators, or damage and malfunction of the device.

Failure in observing the following could result in injuries

●Do not push the key with a pointed article because it damages the key and cause

a failure.

●When the case gets dirty,wipe it on the wring cloth holding neutral detergent.

Prohibit to use the following because they hurt the surface of the case.

※ Organic Solvent(Thinner,Benzine etc.)
※ Storong Acidic or Strong Basic

●Do not sprinkle water on the ULE.

8.Installation

9.Wiring

10.Part names & Functions(Thermostat)

BO

DY

L

oad

Power for load

L

oad

Relay output

Relay output

Power relay,

Electromagnetic

Swich etc.

Power relay,

Electromagnetic

Swich etc.

Power for load

OFF

ON

SET 1

OFF

ON

SET 2

O N 2 O N 1

SEL

ENT

THERMO EYE-U

Turn ON when control
output is ON.

■SET KEY(SEL)

■SET KEY(UP)

■SET KEY(DOWN)

■SET KEY(ENT)
Return to the current

key is pushed.

Select each set mode

Set Temp. increases

Set Temp. decreases

temp. mode when this

when this key is pushed.

when this key is pushed.

when this key is pushed.

■LED FOR OUTPUT DISPLAY

Display the Current

■DETECTED TEMP./SET

TEMP. DISPLAY

Detected Temp. or the
SET Temp.

Step 1.

Step 2.

Terminal ⑥, ⑦ : Control output for

Terminal ⑧, ⑨ : Control output for

■SETTING MODE LED
Blinking the LED means
setting can be changed.