Safety Instructions

 

Tx62, TTSP-RT0111, TTSP-

CT1121

Modular thermometer

TR62 with resistance insert (RTD)

TC62 with thermocouple insert (TC)

Explosion-protected, for screwing into a

thermowell

 

ATEX Ex eb IIC T6...T1 Gb

0

Document: XA01137T

Safety instructions for electrical apparatus for explosion-

hazardous areas according to Directive 2014/34/

EU  

  5

XA01137T/09/EN/02.16

71347532

Содержание T 62 Series

Страница 1: ...R62 with resistance insert RTD TC62 with thermocouple insert TC Explosion protected for screwing into a thermowell ATEX Ex eb IIC T6 T1 Gb 0 Document XA01137T Safety instructions for electrical apparatus for explosion hazardous areas according to Directive 2014 34 EU 5 XA01137T 09 EN 02 16 71347532 ...

Страница 2: ...uropeas pertinentes Las directivas normas y documentos de aplicación se indican en la declaración de conformidad ET Ohutusjuhised plahvatusohtlikus keskkonnas kasutatavate elektriseadmete kohta Kui Te ei saa käesolevast juhendist aru võite meilt tellida Teie riigikeelde tõlgitud juhendi EL vastavusdeklaratsioon Tootja Endress Hauser kinnitab juurdelisatud vastavusdeklaratsiooni esitamisega ja CE m...

Страница 3: ...r este manual pode encomendar nos directamente uma cópia na sua língua Declaração de conformidade CE Com esta declaração de conformidade e a aplicação da marca CE o fabricante Endress Hauser garante que o produto obedece às directivas europeias a aplicar As directivas normas e documentos são apresentadas na declaração de conformidade RO Indicaţii de siguranţă pentru mijloacele de producţie electri...

Страница 4: ...XA01137T Tx62 TTSP RT0111 TTSP CT1121 4 Endress Hauser ...

Страница 5: ...dress Hauser 5 Tx62 TTSP RT0111 TTSP CT1121 Table of contents Associated documentation 6 Supplementary documentation 6 Certificates 6 Safety instructions General 7 Safety instructions Special conditions 8 Temperature table 8 Connection data 9 ...

Страница 6: ...TI01024T 09 EN Modular thermometer TR62 and TC62 Supplementary documentation Explosion protection brochure CP021Z 00 The Explosion protection brochure is available In the download area of the Endress Hauser website www endress com Download Advanced Documentation Code CP021Z Certificates Declaration of Conformity 4 ...

Страница 7: ...ions Install the device according to the manufacturer s instructions and any other valid standards and regulations e g IEC 60079 14 Seal the cable entries tight with certified cable glands for type of protection Ex e and an appropriate temperature range of the ultimate application Seal the cable entries tight with certified cable glands min IP54 IP6X according to IEC 60529 During operation the cov...

Страница 8: ...parts which shall have a degree of protection of at least IP54 in compliance with EN IEC 60079 0 and EN IEC 60079 7 and its ultimate application For assure that the temperature assembly has a degree of protection of at least IP54 the user has to provide a thermowell or equivalent component at the process side Sensors are to be mechanically protected by thermowell The thermometer must be installed ...

Страница 9: ...ient temperature housing T5 50 Tp 88 C 40 Ta 88 C T6 50 Tp 73 C 40 Ta 73 C 1 Maximum process pressure see relevant Technical Information Connection data Type Electrical data TR62 TC62 TTSP RT0111 TTSP CT1121 U 5 V DC I 10 mA Category Type of protection ATEX Type II 2G Ex eb IIC T6 T1 Gb TR62 TC62 TTSP RT0111 TTSP CT1121 ...