Proc Sheet 1 09
myC5-2
REMOVING / REPLACING THE EQUIPPED
ELECTRONIC BOARD
1/2
________________________________________________________________________________________________
Ref. SCT U38 SSC DTS 0024 – Index B - February 15, 2005
Page 5-28
4.57 Tools :
- Cross shaped screwdriver
- Tweezers
4.58 Preliminary operation
1. Remove the battery (
Proc sheet 0 01
).
2. Remove the back cover (
Proc sheet 1 01
).
4.59 Removal procedure :
1. Liberate the electronic board (1) by pushing the two stop pins (5) to outside, by means of tweezers
2. Lift equipped electronic board up (1) to liberate it of the front cover
3. Unsolder the flex PCB (4) from the electronic board (1)
4. Open Zif connector lock (3) by lifting lock up
5. Remove delicately the flex PCB (4).
6. Remove the equipped electronic board (1)
4.60 Placement procedure :
1. Insert the flex PCB (4) into Zif connector (2) on the new equipped electronic board (1)
2. Press Zif connector lock (3),into locked position
3. Flux and solder the flex PCB (4) on the electronic board (1)
4. Replace the equipped electronic board (1) in its housing
4.61 Further operations :
1. Replace the back cover (
Proc sheet 1 01
).
2. Replace the battery pack (
Proc sheet 0 01
).
3. Carry out the radio test (
Test Sheet 04
).
Содержание myC5-2
Страница 16: ...Technical Site Documentation myC5 2 Ref SCT U38 SSC DTS 0024 Index B February 15 2005 Page 2 7...
Страница 23: ...Technical Site Documentation myC5 2 Ref SCT U38 SSC DTS 0024 Index B February 15 2005 Page 3 14...
Страница 29: ...Technical Site Documentation myC5 2 Ref SCT U38 SSC DTS 0024 Index B February 15 2005 Page 3 20 SYMPTOM SHEETS...
Страница 41: ...Technical Site Documentation myC5 2 Ref SCT U38 SSC DTS 0024 Index B February 15 2005 Page 4 32 TEST SHEET...