Initial Installation Procedure
The Initial Installation Procedure consists of two stages: (1) Preparing the
MorphoAccess cables/wires for installation, and (2) Positioning and preparing
the MorphoAccess for final installation against the mounting surface.
Stage 1: Preparing the MorphoAccess cables/wires for
installation
1. Identify the MorphoAccess cables that will be wired for your
particular installation requirements, for example, power,
Wiegand, or RS-485.
Note:
The Ethernet cable comes prewired for 568B with a
standard RJ45 socket installed. The interface cables have
a protective cover placed over the end of each cable. If
the interface cables are used for an installation, remove
the protective cover in order to perform the necessary
wiring.
2. Familiarize yourself with the cable wire diagrams located in
Appendix 1 of this installation guide.
3. Prepare the MorphoAccess cables for connection to the
building cables as follows:
a. Shorten the MorphoAccess cable stubs as necessary for
each installation.
b. Strip one inch of the cable insulation from the end of each
cable you will be using.
Note:
Be careful not to cut the individual wires within
the cables.
c. Strip 1⁄4 - 1⁄2 inch of insulation from the end of each individual
wire you will be connecting.
Note:
If you are using self-tapping wire connectors, this
step may not be necessary.
4. Prepare the building cables for installation in the same manner
as described above for the MorphoAccess cables.
Initial installation
Содержание MorphoAccess 200E
Страница 1: ......
Страница 2: ......
Страница 4: ...ii ...
Страница 9: ...5 General description Rear View Wiegand RS 485 Power Ethernet Multi function Wall Gasket Location ...
Страница 29: ...25 Appendix 1 Rear View Location of Cables Multi function Ethernet Power Wiegand RS485 ...
Страница 34: ......
Страница 35: ......
Страница 44: ......
Страница 45: ......
Страница 47: ......
Страница 111: ......
Страница 112: ......