Installation and User Guide - N56717020101
Page A0-2
Reproduction and communication in any form prohibited without the written permission of
(
PORTS SECURITY LEVEL
Port safety level for the 19" subrack access
The connectors are identified on the front panels of the equipment (cards or motherboard).
Connectors
Function
Security
level
PWRA/PWRB
Power supply
SELV
1
PWR
Power supply
SELV
Motherboard
SYNC
G.703 2 Mbit/s synchronization Ports
SELV
E1 INPUT & E1 OUTPUT
G.703 2 Mbit/s Ports
SELV
MNGT
Other equipment connection
SELV
COMM
VT100 local supervision
SELV
ETH
Ethernet LAN remote supervision
SELV
LOOPS
Loops and remote signaling
SELV
ADR ICI 1.x Card
TR and REC
G.957 and G.958 STM-1 IC1.1 or IC1.2 Optical
Laser class 1
Dangerless
EOW and AUX
Engineering Order Wire
SELV
ADR LAN1 Card
ETH
Ethernet Port
SELV
ADR 21E120 Card
E1 INPUT & E1 OUTPUT
G.703 2 Mbit/s Ports
SELV
)
The 19" subrack must be mounted only in racks with a bottom part that is
closed or fitted with a class V1 or HF1 or better air filter, or that stand on a
non-flammable floor..
Safe earth requirement
This equipment must be installed only by skilled personnel. For compliance, the protective earth
terminal must be connected to a safe earth with an impedance Z of less than 5 Ohms.
)
Handling precaution: For any work to be carried out inside the equipment, an
antistatic wrist strap must be worn.
Lithium Battery
)
Warning : If the battery is incorrectly replaced there is a risk of explosion.
Only replace with same type battery or equivalent type recommanded by the
manufacturer
Dispose of used battery according to manufacturer instructions
In ADR155C, battery replacement may only be done by return Supply Support Department.