1 - INSTALLATION AND COMMISSIONING
Installation and User Guide - N56717020101
Page A1-16
No reproduction or communication without the written consent of
SAGEM SA
1.3.4 - Connecting on ADR LAN1 card
ADR LAN1
ETH
10
/
100 HALF
/
FULL
ETH
1 : TX_ETH_TIP 5 : NC
2 : TX_ETH_RING 6 : RX_ETH_RING
3 : RX_ETH_TIP 7 : NC
4 : NC 8 : NC
STATUS
10/100
Yellow LED : Ethernet interface bite rate
ON
: 100 Mbit/s
HALF/FULL
Yellow LED : Ethernet interface type
(Half or Full Duplex)
ON
: Full duplex
Contact 8
Contact 1
NC : Reserved
LED
STATUS
Green Red
ON
OFF
Card in service
ON
ON
Card in alarm
OFF
OFF
Hardware default (fuse)
OFF
ON
Card out of service
Flashing
Autotest default
Yellow LED : link status
ON
: correct link
Green LED : traffic status
ON
: on reception
Figure 1-5 – Connecting ADR LAN1 card input
"ETH" Interface :
Port
Traffic Ethernet interface operating at 10 or 100 Mbit/s in half-duplex or full-
duplex mode according to the mode used by the interlocutor (dynamic
adaptation of the Ethernet port on each new log-in of the interlocutor),
Connector
Ethernet 10 or 100 BaseT - RJ48 Type (Shielded RJ45).
Pin 8
Pin 1
Front view
Pin N°
Signal name
Comments
1
TX_ETH_TIP
Ethernet output (hot point)
2
TX_ETH_RING
Ethernet output (cold point)
3
RX_ETH_TIP
Ethernet input (hot point)
4
NC
Reserved
5
NC
Reserved
6
RX_ETH_RING
Ethernet input (cold point)
7 and 8
NC
Reserved
NOTE: Two LEDs are linked to the "ETH" interface:
•
LED, "Activity", green colour
: Trafic status indicator,
•
LED, "Link", yellow colour
: Link status indicator.
Electrical characteristics compliant with the IEEE 802.3U