1 - INSTALLATION AND COMMISSIONING
Installation and User Guide - N56717020101
Page A1-8
No reproduction or communication without the written consent of
SAGEM SA
NOTE: Two LEDs are linked to the "ETH" port:
•
LED, "Activity", green colour
: Trafic status indicator,
•
LED, "Link", yellow colour
: Link status indicator.
1.3.2.2 - Management and Administration ports
"COMM" Interface:
Ports
RS232, connecting VT100 standard console or emulation
Bit rate
19200 bauds (8 data bits, no parity bit and 1 stop bit),
Connector
Female 9-way HE5
6
5
9
1
Pin N°
Signal name
Comments
1
DCD
Connected to DSR
6
DSR
Data Set Ready (to DCE)*
2
RX
Received data (to DCE)*
7
RTS
Request To Send (from DCE)*
3
TX
Transmitted data (from DCE)*
8
CTS
Clear To Send (to DCE)*
4
DTR
Data Terminal Ready (from DCE)*
9
RI
Ring Indicator (not connected)
5
GND
Ground
* The ADR155C is seen as DCE
Connection cable See below.
1
9
5
6
1
6
9
5
Wiring diagram
VT100 or PC
side
Male 9-way connector
Equipment side
"COMM"
Female 9-way connector