TECHNICAL DATA FOR SAGE RIO MODELS SIX/SRX
BRIDGE CIRCUIT
24 VDC
110 VAC 50/60Hz
230 VAC 50/60 Hz
O p e r a t i o n s a n d I n s t r u c t i o n M a n u a l
31
S A G E M E T E R I N G , I N C .
REV. 10-SIX/SRX
Approvals
I max
100 mA
100 mA
100 mA
P max
2.4 watts
2.4 watts
2.4 watts
I nominal
64 mA
64 mA
64 mA
P nominal
1.5 watts
1.5 watts
1.5 watts
I max
100 mA
88 mA
44 mA
P max
2.4 watts
10.1 watts
10.1 watts
I nominal
64 mA
54 mA
27 mA
P nominal
1.5 watts
6.2 watts
6.2 watts
EU Explosive
atmosphere symbol
Equipment
group
II Non-Mining
Equipment
category
2 = High protection
Type of Protection
Flameproof
Gas Groups
IIB = Ethylene
+H2 = Hydrogen
Temperature
Code
Max Surface Temp in
Enclosure = 85˚C
Gas
Gas
Zone I
II 2 G Ex d IIB+H2 T6 Gb
TOTAL METER POWER
24 VDC
110 VAC
230 VAC
HAZARDOUS LOCATION APPROVALS
Sage Rio Gas Flow Meter Type SIX or SRX are ATEX
approved.
Certification No.:
TÜV 12 ATEX 7167 X
II 2 G Ex d IIB+H2 T6 Gb
T
amb
=–40˚F (–40˚C) to +122˚F (50˚C)
Only use Silicone O-Rings for –40˚C which are
certified under DEMKO 07 ATEX 0622294U
UL Certification No. 20141219 - E464988
USL, CNL - Class I, Div 1; Groups B, C, and D
Hazardous Locations
CONFORMANCE
EN 60079-0:2009
EN 60079-1:2007
REQUIREMENTS
The cable entry holes shall be fitted with suitably
certified cable glands or suitably certified stopping
plugs that are capable of maintaining the IP rating
of the equipment.
• Do not open when energized.
• Do not open when an explosive atmosphere
might be present.
• Customer repair of the product (or replacement
of components) is not allowed.
• If the equipment is used in a manner not specified
by the manufacturer, the protection provided by
the equipment may be impaired.
• Permanently connected equipment shall employ a
switch or circuit breaker as a means for disconnec-
tion in the installment.
• Switch or circuit breaker must be suitably located
and easily reached.
• Switch or circuit breaker must be marked as the
disconnecting device for the equipment.
• The internal grounding terminal shall be used as
the equipment grounding means and that the
external terminal is only a supplemental bonding
connection where local authorities permit or
require such a connection.
Содержание RIO SIX
Страница 2: ......
Страница 6: ......
Страница 7: ...Section GETTING STARTED A ...
Страница 8: ......
Страница 25: ...Section STYLES AND FEATURES B ...
Страница 26: ......
Страница 32: ...S A G E M E T E R I N G I N C O p e r a t i o n s a n d I n s t r u c t i o n M a n u a l 32 REV 10 SIX SRX ...
Страница 39: ...Section DIAGNOSTICS D ...
Страница 40: ......
Страница 45: ...Section WARRANTIES AND SERVICE WORK E ...
Страница 46: ......
Страница 51: ...Section MODBUS F ...
Страница 52: ......
Страница 61: ...Section HART G ...
Страница 62: ......
Страница 71: ...G Section APPENDIX H ...
Страница 72: ......