122
Unless stated otherwise all dimensions are in mm
Assembly
Slide the Adjustable Inner Panels (MK3) into position.
Secure using the captive M12x35 Bolt/Nut “Stoppers” of the Adjustable Outer Panels
(MK2), top and bottom.
Tighten the M12x90 Hex. Head Setscrews, top and bottom, of the Adjustable Inner
Panels (MK3).
Adj. Inner Panel
M12 x 90
Hex. Head
Setscrew
M12 x 35
Bolt Nut
“Stopper”
R6/T9
Perforated
sheets not
shown for
clarity.
WARNING
Warning!
Do NOT walk or store materials on top of mesh.
VISUAL CHECK
Ensure P
anel is correctly positioned and securely fixed to the
Main Frame.
NOTE
Note
For delivery purposes, units can NOT be wider than 2.9m.
Check local transport regulations.