background image

Quantum™ MT™ Installation Instructions 

Pg. 7 of 8 

Testing Lock Functionality 

Testing Lock Functionality 

  

Insert a Construction keycard in the keycard reader. Be sure that the green light flashes for five seconds 
while the exterior lever remains operable. If the green light does not flash, refer to the table below. 

Insert a Construction keycard in the keycard reader. Be sure that the green light flashes for five seconds 
while the exterior lever remains operable. If the green light does not flash, refer to the table below. 
  
  

 

Lock Communication 

 

Electronic Function Description 

 

 
 

Red and green LEDs flash

  

 

Time and date not set, use the LPI to reset time and date 

nine times simultaneously 
 
 
Yellow LED flashes 12 times

   

Dead bolt is thrown or switch cam is not properly aligned 

 
 

Yellow LED flashes two times 

 

Keycard not allowed OR keycard cancelled by new keycard 

 
 

Red and green LEDs flash 

 

 

Low battery (contact the SAFLOK service department) 

alternately nine times 

 
 

Yellow and red LEDs flash 

 

 

Bad keycard read or corrupted data (may require new  

two times simultaneously

  

keycard) 

 
 

Red LED flashes two times

 

Keycard not read (keycard inserted upside-down, wrong end, 
wrong key?) 
 

 

© SAFLOK™ 

INS_QTMCARDMT 

 2/16/2012 

Содержание Quantum MT

Страница 1: ...6 XX Card Reader Assembly A20950 COLOR Rubber Gaskets external applications only Screw Pack A29070 COLOR All information contained herein including but not limited to product pricing and other intelle...

Страница 2: ...appropriate for the SAFLOK mortise lock Drill fixture If you are using a SAFLOK drill fixture position and clamp the fixture on the door The fixture has two positioning posts that rest inside the mort...

Страница 3: ...into the pocket 4 Attach the mortise front plate to the door using the two mortise screws 12 x 1 1 4 screws for wood doors 12 24 x 3 8 screws for metal doors Be sure that the screws are fully tightene...

Страница 4: ...cable through the reader cutout in the door 3 Position the inside trim on the inside of the door 4 Secure inside trim to the card reader assembly using three 8 32 x 1 1 4 screws Important Do not full...

Страница 5: ...B mortises or at the bottom 6 00 position for standard mortises see Fig 3 The retaining ring should rest on the switch cam when fully inserted the proper positioning of the cam will allow the door to...

Страница 6: ...6mm Torx Screws Fig 4 14 Program the lock using the Lock Programmer and Interrogator LPI probe Test the functioning of the lock as discussed in the following section and in the programming manual befo...

Страница 7: ...h refer to the table below Lock Communication Electronic Function Description Red and green LEDs flash Time and date not set use the LPI to reset time and date nine times simultaneously Yellow LED fla...

Страница 8: ...nserted and withdrawn freely Yellow light flashes twice when incorrect keycard is used Red light flashes twice if keycard is used incorrectly and cannot be read e g a credit card is used Green light f...

Отзывы: