9
/
34 • GAFM-II-10.12
The
insert battery is delivered with a partial charge
for the initial test of the device.
We recommend
to entirely charge the battery
before continuous use (see also chapter
„D“ MAINT CARE).
a.
To place the battery in the device, first loosen
the battery compartment safety
screw
(see illustration) with a screwdriver counter-clockwise just one or two turns
until the screw head corresponds with the outer surface of the device’s housing.
Stop if there is noticeable resistance, do not use force,
this may damage the
battery compartment.
b.
Now push the battery into the battery compartment (see illustration) with contacts
first and inscription
LONG
(
™
)
pointing up
until the battery audibly and noticeably
clicks into place.
c.
Now fasten the battery securing screw by turning it clockwise;
again, stop if there
is noticeable resistance.
d.
This
operation is necessary to prevent the battery from falling out.
By no
means
let the lead-acid battery fall out of the device
as it might break and cor-
rosive acid might escape.
e.
The FlowMarker is
now ready for operation.
If the battery is empty it has to be charged* with the battery charger,
the red LED “BAT-
TERY” first flashes, afterwards it lights up permanently.
(*See for this section „D“
MAINTENACE AND CARE „Charging the battery”.)
In this way the user can recognize early on that a recharging of the battery is impending,
one can therefore usually performing its current investigation until to its final end.
If the
red LED lights up permanently,
there is a
remaining battery capacity
of approx-
imately
2 - 6 minutes
for producing fog
depending on the battery-conditions. After that,
the unit turns off itself completely to protect the battery against deep discharge.
NOTE:
A short flash of all LED's happens when switching the power
ON
or
OFF
, it is a
signal monitoring. In these cases, the brief flash of the red LED is no sign of a battery
defect.
For optimum performance, de-aerate the fluid ways in the device
after every refill.
a.
Activate and heat up the
FlowMarker
®
by pushing the blue fog button, the green
LED will flash.
b.
The heating-up takes about 30 seconds when the device is cold.
After complete
heat-up
(green
LED “Ready”
lights up
permanently
!)
hold the device vertically, with its nozzle or application tube pointing up. Press the
fog button shortly to start the fog production (white LED lights up) for about 45 se-
conds, until the fog comes out evenly. A pushing of the blue button stops the fog
production than.
De-aerating can only be carried out in upward direction!
INSERTING
BATTERY
DE-AERATING
FLUIDWAYS
battery
compartment
safety screw