2023 Copyright Safewaze
7
FIGURE 7 - INSTALLATION
021-4068 / 021-4069
1. The 021-4068 and 021-4069 are for use in a horizontal orientation only. They are not designed for use in vertical
applications.
2. The work location should be free of debris, and other materials or equipment that could interfere with the proper
operation of this equipment.
3. Inspect the steel beam to which the anchor will be attached. User should inspect for the following hazards. These
hazards include, but are not limited to, excessive corrosion, cracks, severe rust, excessive paint, spray applied fire
proofing, electrical hazards, etc...
4.
The 021-4068 can be installed on beams 3-1/2” to 14” in width, with a maximum flange thickness of 1-1/4”. The
021-4069 can be installed on beams 12” to 30” in width, with a maximum flange thickness of 2-5/8”. User must
inspect the 021-4068 and 021-4069 prior to each use. If damage or defects such as, but not limited to, excessive
corrosion, deformation of any component, improper function of the adjustment levers, fall protection connection point
damaged or missing, chemical or excessive heat exposure are present, the anchor MUST BE REMOVED FROM
SERVICE.
5.
After inspection of the installation location, adjust the Beam Anchor in to fit the beam dimensions. Ensure the steel
I-Beam is within the acceptable dimensions for the Beam Anchor being utilized (See Table 1). Width adjustment is
made by depressing the Adjustment Levers on each Clamp Assembly and sliding the assemblies in or out to fit beam
dimensions (See Figure 7, Dwg.1 and Dwg. 2).
6.
With the anchor properly fitted to the I-Beam, the user can connect their fall protection device to the anchor
(See Figure 7, Dwg. 3).
7. The 021-4068 and 021-4069 are designed to slide along the beam in unison with the user’s movement. All can be
used in either overhead or foot level tie off applications (See Figure 10 and 11).
Dwg. 1
Dwg. 2
Dwg. 3
180° Swivel
021-4075
1-1/4” Max
Flange Thickness
3-1/2” to 15”
Acceptable Beam Dimensions
021-4075
3-1/2” to 15” Width
Up to 1-1/4” Flange Thickness
FIGURE 8 - REQUIRED INSTALLATION DIMENSIONS
TABLE 2 - INSTALLATION