background image

  

322 Industrial Court, Concord NC, 28025

  

Phone: 704-262-7893

  

Email: [email protected]

  

Web: safewaze.com

 

 Fax: 704-262-9051

I

I

I

I

I

HOLE SIZE

1-3/4” to 6” Ø

(A) Min Dis

t. from any 

edge

(B)

Min. 

Thickness

Hole Requirement Specifications

Substrate Material

(B) Min. Thickness in inches

(A) Min. Dist. in inches from edge/corner

Concrete

Concrete

Metal Grate

Steel

Steel

Corrugated Metal

12” (30.5 cm)

4” (10 cm)

4” (10 cm)

.25” (.635 cm)

Metal Grate

Corrugated Metal

8” (20.32 cm)

24” (60.96 cm)

2.0” (5.08 cm)

.396” (1.00 cm)**

HOLE SIZE

1-3/4” to 6” Ø

(A) Min Dis

t. from any 

edge

(B)

Min. 

Thickness

HOLE SIZE

1-3/4” to 6” Ø

(A) Min Dis

t. from any 

edge

HOLE SIZE

1-3/4” to 6” Ø

(A) M

in Di

st. fro

m an

y edg

e

**  .396” (1.00 cm) minimum thickness based on use of wood      

      bracing as indicated 

Drop Through Anchor

Complies with OSHA 1910.66, OSHA 1926.502, ANSI Z359.1-2007

020-4020 (2’ / .61m)
020-4021 (8.5’ /  2.6m)

Do not use in wet or uncured 

concrete.  Use in normal weight 

concrete with a compression 

strength of at least 3,000 PSI 

(20.7 MPa).  Use ONLY on 

concrete decks with a minumum of 

4” thickness.  This anchor is to be 

used in an overhead application 

ONLY. 

All persons using this equipment

must read, understand, and follow

all instructions.  Failure to do so 

may result in serious injury or 

death. 

Use only compatible connectors.  Avoid all physical hazards including thermal, electrical 

and chemical sources.  Inspect before each use.  In addtion, a competent 

person must inspect this equipment at least annually.  

DO NOT TOUCH FALL 

PROTECTION 

ANCHOR WHEN IN 

USE!

Materials: 

Coated Steel, 

Stainless Steel, Galvanized 

Aircraft Cable

020027

Min. Hole Diameter for Installation: 1-3/4” (4.445 cm)

Max. Hole Diameter for Installation: 6” (15.24 cm) 

INSTALLATION

INSTALLATION AND USE EXAMPLE

DROP THROUGH ANCHOR COMPONENTS

WARNING

 

    

   

•  Users should consult with their doctor to verify ability to safely absorb the forces of a fall arrest event.  

Fitness level, age, and other health conditions can greatly affect an individuals ability to withstand fall 

arrest forces. Women who are pregnant, individuals considered minors must not use any SafeWaze 

equipment. 

•  Never alter any part of a lanyard or add/remove components.  SafeWaze shall not be held 

responsible for injury or death due to tampering.

•  Anchors that are exposed to fall arrest forces MUST be IMMEDIATELY removed from service and 

destroyed.  

•  Failure to follow these instructions and warnings could result in serious injury or death in the event 

of a fall.

•  A preplanned rescue procedure in the event of a fall is required.  The rescue plan must be specific to 

the project.  The rescue plan must allow for employees to rescue themselves, or to be promptly rescued 

by alternative means. 

•  Harnesses or connectors selected for use with any SafeWaze anchor must be compatible in size and 

configuration. User must ensure compatibility of snap hooks, carabiners and other connectors.  Any 

connection which could allow disengagement must be eliminated. Snap hooks and carabiners must be 

self locking and self closing and must never be hooked to each other. 

•  A Competent Person must conduct an analysis of the workplace and anticipate where workers will be 

conducting their duties, the route they will take to reach their work, and the existing and potential fall 

hazards they may be exposed to.  The Competent Person must choose the fall protection equipment 

to be utilized.  

•  Do not misuse equipment.

•  Equipment designated for fall protection must never be used to lift, hang, support or hoist tools or 

equipment unless specifically certified for such use.    

•  SafeWaze  Anchors shall be inspected prior to each use by the user and at least every 6 months by 

a Competent Person.  Annual inspections shall be documented.  Severity of conditions during use may 

necessitate increased frequency of documented inspections.  

•  Anchors that fail inspection MUST be removed from service.

•  Prior to each use, inspect the anchor for deficiencies or damage, including, but not limited to, sharp 

edges, rough edges, deformations, corrosion, pits, burrs, chemical exposure, extreme heat exposure, 

kinked, bird nested, or otherwise damaged cable, and damaged, missing or illegible labels. If any 

deficiencies or defects are found, the anchor must IMMEDIATELY be removed from service.

•  The anchor must be inspected at least every 6 months by a Competent Person other than the user.  

Competent person inspections must be recorded in the inspection log included in this manual and on the 

inspection grid label on the anchor. 

INSPECTION

MAINTENANCE & STORAGE

WARRANTY

The Drop Through Anchor can be cleaned with water and mild soap if necessary.  User should remove 

all dirt, possible corrosives, and contaminants from the anchor prior to, and after each use.  Never use 

any type of corrosive substance to clean the anchor.  

Excess water should be blown out with compressed air.  Hardware can be wiped off with a clean, dry 

cloth.

When not in use, store the anchor in a cool dry area where it will not be exposed to extreme light, 

extreme heat, excessive moisture, or possibly corrosive chemicals or materials.   

SafeWaze warrants its products are free from defects in materials and construction under normal use 

and service.  Liability is not accepted for abuse, modification, improper use, destructive activity and 

contaminated exposure. 

INSPECTION LOG

Date

Inspection Items 

Noted

Corrective Action

Initials

LABELS

1. Under guidance of a Competent or Qualified Person, a suitable anchor point must be chosen that 

meets the strength requirement, minimizes free fall, and reduces swing fall hazards. SafeWaze Drop 

Through Anchors are only authorized for use on a Horizontal surface above the user’s location.

2. SafeWaze Drop Through Anchors can be installed on any structure that meets the strength 

requirements as defined in the SPECIFIC ANCHOR APPLICATIONS section of this manual for Personal 

Fall Arrest.

3. To install a Safewaze Drop Through Anchor, the user must create, or use an existing through hole in 

either concrete, steel, or metal grating that meets the specifications indicated below (See Figure 6).  

4. Once the appropriate sized through hole is created or located (See Dwg. 1-4), install the Drop 

Through Anchor by placing the cable through the hole from the top side (See Dwg. 5). 

5. After lowering the cable assembly of the Drop Through Anchor through the hole, ensure that the plate 

sits flush on the mounting surface (See Dwg. 6) 

6. After installation, the user can safely hook to the PFAS Connection Point, utilizing a connecting device 

attached to the Dorsal D-ring of a Full Body Harness (See Dwg. 7)  

7. SafeWaze Drop Through Anchors are designed as a fall arrest anchorage for a single user with a 

maximum weight capacity of 310 lbs. including tools and equipment.

FIGURE 5 - ANCHOR COMPONENTS

FIGURE 6 - INSTALLATION

B

C

D

E

F

A

Cable to Plate Connection Hardware

B

C

D

E

F

Anchor Plate

Wire Rope 

Swivel Connection

Abrasion Sleeve

PFAS Attachment Point

Drop Through Anchor Components

A

Dwg. 1

Dwg. 2

Dwg. 3

Dwg. 6

Dwg. 5

Dwg. 4

Dwg. 7

LOAD IN

DICATO

R

LOA

D IN

DIC

ATO

R

A

FALL-ARREST

32

2 I

nd

us

tria

l C

ou

rt, 

C

on

co

rd

, N

C

 2

80

25

P: 

(7

04

) 2

62

-7

89

3 o

r F

: (7

04

) 2

62

-9

05

1

W

W

W

.S

A

FE

W

A

ZE.
COM

SE

LF

 RETR

A

CTING L

ANY

ARD

SEL
F RE
TR
A

CTI

NG
 L

A

NY
ARD

AN

SI 

Z3

59

.1

4 &

 A

N

SI 

A1

0.3

2

O

SH

A 1

91

0.6

6 &

 O

SH

A 1

92

6.5

02

Fal

l A

rrest 
Sys

tems 

 C

on

fin

ed

 S

pace
 

 E

ng

in

ee

rin

 R

esc
ue 

Sys

te

ms

7’

7’

Drop Through Anchor

Complies with OSHA 1910.66, OSHA 1926.502, ANSI Z359.1-2007

020-4020 (2’ / .61m)
020-4021 (8.5’ /  2.6m)

Do not use in wet or uncured 

concrete.  Use in normal weight 

concrete with a compression 

strength of at least 3,000 PSI 

(20.7 MPa).  Use ONLY on 

concrete decks with a minumum of 

4” thickness.  This anchor is to be 

used in an overhead application 

ONLY. 

All persons using this equipment

must read, understand, and follow

all instructions.  Failure to do so 

may result in serious injury or 

death. 

Use only compatible connectors.  Avoid all physical hazards including thermal, electrical 

and chemical sources.  Inspect before each use.  In addtion, a competent 

person must inspect this equipment at least annually.  

DO NOT TOUCH FALL 

PROTECTION 

ANCHOR WHEN IN 

USE!

Materials: 

Coated Steel, 

Stainless Steel, Galvanized 

Aircraft Cable

020027

Min. Hole Diameter for Installation: 1-3/4” (4.445 cm)

Max. Hole Diameter for Installation: 6” (15.24 cm) 