8
Figure 8
SYSTEM
1 USER
2 USERS
3 USERS
4 USERS
F (kN)
M
(kNm)
F (kN)
M
(kNm)
F (kN)
M
(kNm)
F (kN)
M
(kNm)
1
15
1.125
15
1.125
18
1.35
22
1.65
2
15
1.125
15
1.125
18
1.35
22
1.65
3
15
1.125
15
1.125
18
1.35
22
1.65
4
15
1.125
15
1.125
18
1.35
22
1.65
5
15
1.125
15
1.125
18
1.35
22
1.65
6
15
2.25
15
2.25
18
2.7
22
3.3
3.1.4 Cable Guide Spacing
Cable guides shall be space no greater than 8m apart.
3.2
Fixings
3.2.1 General
All fixing used to attached the V-Line system to the substrate that were not supplied by
Safetylink shall be M12 (1/2") or M16 (5/8") in diameter. Fixing shall be stainless steel grade
316 or 304 or hot dip galvanised or zinc plated steel grades 8.8 or 8. Fixing shall be installed
with spring washers, lock nuts or thread lock adhesive to prevent loosening.
⚠
SafetyLink does not recommended the use of zinc plated fasteners in a corrosive or
outdoor environment.
3.2.2 Concrete - DonutLink
SafetyLink's DonutLink M12 Concrete Stud CON-M12X160-DONUT
or
M16 Concrete Stud
CON-M16X160-DONUT are to be installed with chemical adhesive CON-CHEM-FISV.300.
1 Mark the location for the hole.
⚠
The location shall be no less than 150mm from any edge.
⚠
Minimum concrete thickness shall be no less than 150mm.
⚠
The stud shall only be installed in concrete 32MPa or greater.
⚠
Consult a structural engineer if there is any doubt of the suitability of the structure.
2 Set the drill depth and diameter hole for the desired stud.
3 Clean the hole, ensuring it is free of moisture and dust.
4 Inject the adhesive in to the hole as per the manufacturer's instruction.
5 Insert the stud to full depth, 35mm of the stud should remain above the surface. Wipe away
any adhesive expelled from the hole.
⚠
Ensure enough adhesive was used, the adhesive should finish flush with the concrete.
6 Once the adhesive is cured, install the spring washer and tighten the Donut to 70Nm.
The DonutLink can be proof loaded with the Pull Test Adaptor (DONUTLINK-ADP) and a
Hydrajaws portable tension tester.