FIXED LADDERLINK 

 TILED ROOF LADDER SUPPORT BRACKET 

 

INSTALLATION FOR TILED ROOFS 

1.

 

To install the LadderLink simply remove roof tiles at the desired location. 

2.

 

Place the ladder bracket onto the batten, ensure a rafter is centred below the ladder bracket. 

3.

 

Adjust the ladder bracket so the rolled section is centred over the gutters front edge, as shown in the diagram 
below. 

4.

 

Once the ladder bracket is in the desired location, install three (3) x 65mm 12g hex head roofing screws through 
the ladder bracket and into the roof batten below (recommended to pilot drill holes). 

5.

 

Cut a short tile batten to fit as a spacer under the ladder bracket between the rafter and ladderlink. 

6.

 

Using  one  (1)  x  100mm  14g  hex  head  roofing  screw,  anchor  the  ladder  bracket  to  the  rafter  below 
(recommended to pilot drill holes). This should be centred and installed 50mm down from the top edge of the 
ladder bracket (see below diagram). 

7.

 

Ensure that a minimum of three (3) x 12g 65mm and one (1) x 14g x 100mm roofing screws anchor the ladder 
bracket to the structure. 

8.

 

Ensure the timber structure is secured in accordance with current Building Codes.   

 

 

 

 

Содержание LADFX001

Страница 1: ... entire handbook before installing SafetyLink products All products must be installed in accordance with SafetyLink s installation handbook using only products supplied by SafetyLink Pty Ltd Failure to follow all warnings and instructions may result in a serious injury or death SafetyLink Pty Ltd AU 1300 789 545 INT 61 2 4964 1068 FAX 61 2 4964 1069 info safetylink com www safetylink com ROOF ANCH...

Страница 2: ...FOR METAL ROOFS UNDER ROOF SHEETING 6 FIXED LADDERLINK METAL ROOF LADDER SUPPORT BRACKET 7 INSTALLATION FOR METAL ROOFS ON TOP OF ROOF SHEETING 7 FIXED LADDERLINK TILED ROOF LADDER SUPPORT BRACKET 8 INSTALLATION FOR TILED ROOFS 8 FIXED LADDERLINK WALL MOUNTED LADDER SUPPORT BRACKET 9 FIXING TO TIMBER WALL PARAPET 9 FIXING TO CONCRETE WALL PARAPET 9 APPENDIX DIAGRAM 2 ANCHOR POSITIONING LAYOUT 10 E...

Страница 3: ...ns A personal energy absorber or a fall arrest device with a personal energy absorber must be used to connect to all SafetyLink Anchorages and or Strops MAINTENANCE PERIODIC INSPECTIONS All items of equipment which are in regular use shall be subjected to periodic inspection and servicing These regular scheduled inspections and servicing must be carried out by a competent height safety installer F...

Страница 4: ...acement for a period of 1 one year from the date of shipment This limited warranty applies provided that a defects have arising solely from faulty materials or workmanship b the Products have not received maltreatment inattention or interference c the Products have been installed in accordance with the Company s Installation Handbooks using only products supplied by the Company d accessories used ...

Страница 5: ...t be completed with an appropriate sheet metal bending machine only LadderLink s are made from high tensile aluminium the bender must be set on a high radius to prevent cracking Failure to do so may result in a damaged and unsafe ladder bracket Always use a leash in conjunction with securing points on the LadderLink to secure your ladder once fitted to a ladder bracket Protective coating must not ...

Страница 6: ...location 2 Slide the ladder bracket under the roof sheeting between the sheeting and batten as shown in the diagram below 3 Position the ladder bracket so the rolled section is centred over the gutters front edge 4 Once the ladder bracket is in the desired location re install the hex head roofing screws through the original holes through the ladder bracket and into the roof batten below 5 Ensure t...

Страница 7: ...diagram below 3 Position the ladder bracket so the rolled section is centred over the gutters front edge 4 Once the ladder bracket is in the desired location re install the hex head roofing screws through the ladder bracket ensure the screws go through the roof sheeting and into the roof batten below 5 Ensure that a minimum of three 3 x 12g 65mm roofing screws anchor the ladder bracket to the stru...

Страница 8: ...ired location install three 3 x 65mm 12g hex head roofing screws through the ladder bracket and into the roof batten below recommended to pilot drill holes 5 Cut a short tile batten to fit as a spacer under the ladder bracket between the rafter and ladderlink 6 Using one 1 x 100mm 14g hex head roofing screw anchor the ladder bracket to the rafter below recommended to pilot drill holes This should ...

Страница 9: ...chment see recommended fixing options below Ensure that a minimum of four 4 appropriate fixings are used to anchor the ladder bracket to the structure Fixings should be evenly spaced ideally 50mm in from the LadderLink edges to create a secure installation see below diagram FIXING TO TIMBER WALL PARAPET 1 Drill and install 4 four 14g x 75mm roofing screws recommended to pilot drill holes 2 Ensure ...

Страница 10: ...ALLATION MUST BE CARRIED OUT BY OR UNDER THE SUPERVISION OF A COMPETENT HEIGHT SAFETY INSTALLER ACCESS LAYOUT AND USE OF A SAFETYLINK ANCHOR SYSTEM SafetyLink anchor points are positioned by calculating the pendulum effect this limits the likelihood of a fall past the edge of the roof space The pendulum effect still applies to a flat roof SPACING MUST BE NO GREATER THAN THE RAFTER LENGTH PLEASE CO...

Страница 11: ...mplete access to your roof Detailed comprehensive documentation provided e g installation guides testing results product sheets should be provided SafetyLink can also provide you with a qualified and reputable installer of SafetyLink products Contact our design team at info safetylink com and we can plan your fall arrest system for you 2018 SafetyLink Pty Ltd Australia Patents SafetyLink Pty Ltd h...

Страница 12: ...1 4 2009 CLAUSE 9 5 EQUIPMENT WHICH HAS ARRESTED A FALL OR SHOWS A DEFECT Any piece of equipment including both personal and permanently installed items which has been used to arrest a fall or which shows any defect during operator or periodic inspection shall be withdrawn from service immediately and a replacement obtained if necessary A label indicating the condition or defect should be attached...

Отзывы: