background image

 

IN CASE OF ACCIDENT 

 

 

A FALL RESCUE PLAN AND SAFE WORK STATEMENT MUST BE DEVELOPED PRIOR TO USING 
SAFETYLINK SYSTEMS AND EQUIPMENT.   

 

PERSONS WORKING AT HEIGHTS SHOULD NOT WORK ALONE. 

 

It is critical that before using any SafetyLink Systems a fall rescue plan is in place for any persons suspended 
mid-

air following a fall. Serious injury or death can occur in a matter of minutes, particularly if a person’s 

movement or breathing is restricted or loss of consciousness has occurred. In accordance with your fall 
rescue plan and appropriate first aid procedures it is essential to remove the person from the suspended 
position as quickly as possible.

 

 

IN ACCORDANCE WITH AS/NZS 1891.4:2009 CLAUSE 9.5 

 

EQUIPMENT WHICH HAS ARRESTED A FALL OR SHOWS A DEFECT

 

Any piece of equipment including both personal and permanently installed items, which has been used to 
arrest a fall or which shows any defect during operator or periodic inspection shall be withdrawn from 
service immediately and a replacement obtained if necessary. A label indicating the condition or defect 
should be attached to the equipment, and it should be examined by a competent height safety installer 
who  will  decide  whether  the  equipment  is  to  be  destroyed  or  repaired  if  necessary  and  returned  to 
service. In the latter case, details of any repair shall be documented, and a copy given to the operator.  

 
 

 

 

 

Terms/Conditions/Warranties

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

DISTRIBUTOR: 

Safety

Link

 Pty Ltd | ABN 83 081 777 371 

Phone: 1300 789 545 or +61 2 4964 1068| Fax: 1300 738 071 or +61 2 49641069 

[email protected]   | www.safetylink.com

 

 

Содержание LADFX001

Страница 1: ... entire handbook before installing SafetyLink products All products must be installed in accordance with SafetyLink s installation handbook using only products supplied by SafetyLink Pty Ltd Failure to follow all warnings and instructions may result in a serious injury or death SafetyLink Pty Ltd AU 1300 789 545 INT 61 2 4964 1068 FAX 61 2 4964 1069 info safetylink com www safetylink com ROOF ANCH...

Страница 2: ...FOR METAL ROOFS UNDER ROOF SHEETING 6 FIXED LADDERLINK METAL ROOF LADDER SUPPORT BRACKET 7 INSTALLATION FOR METAL ROOFS ON TOP OF ROOF SHEETING 7 FIXED LADDERLINK TILED ROOF LADDER SUPPORT BRACKET 8 INSTALLATION FOR TILED ROOFS 8 FIXED LADDERLINK WALL MOUNTED LADDER SUPPORT BRACKET 9 FIXING TO TIMBER WALL PARAPET 9 FIXING TO CONCRETE WALL PARAPET 9 APPENDIX DIAGRAM 2 ANCHOR POSITIONING LAYOUT 10 E...

Страница 3: ...ns A personal energy absorber or a fall arrest device with a personal energy absorber must be used to connect to all SafetyLink Anchorages and or Strops MAINTENANCE PERIODIC INSPECTIONS All items of equipment which are in regular use shall be subjected to periodic inspection and servicing These regular scheduled inspections and servicing must be carried out by a competent height safety installer F...

Страница 4: ...acement for a period of 1 one year from the date of shipment This limited warranty applies provided that a defects have arising solely from faulty materials or workmanship b the Products have not received maltreatment inattention or interference c the Products have been installed in accordance with the Company s Installation Handbooks using only products supplied by the Company d accessories used ...

Страница 5: ...t be completed with an appropriate sheet metal bending machine only LadderLink s are made from high tensile aluminium the bender must be set on a high radius to prevent cracking Failure to do so may result in a damaged and unsafe ladder bracket Always use a leash in conjunction with securing points on the LadderLink to secure your ladder once fitted to a ladder bracket Protective coating must not ...

Страница 6: ...location 2 Slide the ladder bracket under the roof sheeting between the sheeting and batten as shown in the diagram below 3 Position the ladder bracket so the rolled section is centred over the gutters front edge 4 Once the ladder bracket is in the desired location re install the hex head roofing screws through the original holes through the ladder bracket and into the roof batten below 5 Ensure t...

Страница 7: ...diagram below 3 Position the ladder bracket so the rolled section is centred over the gutters front edge 4 Once the ladder bracket is in the desired location re install the hex head roofing screws through the ladder bracket ensure the screws go through the roof sheeting and into the roof batten below 5 Ensure that a minimum of three 3 x 12g 65mm roofing screws anchor the ladder bracket to the stru...

Страница 8: ...ired location install three 3 x 65mm 12g hex head roofing screws through the ladder bracket and into the roof batten below recommended to pilot drill holes 5 Cut a short tile batten to fit as a spacer under the ladder bracket between the rafter and ladderlink 6 Using one 1 x 100mm 14g hex head roofing screw anchor the ladder bracket to the rafter below recommended to pilot drill holes This should ...

Страница 9: ...chment see recommended fixing options below Ensure that a minimum of four 4 appropriate fixings are used to anchor the ladder bracket to the structure Fixings should be evenly spaced ideally 50mm in from the LadderLink edges to create a secure installation see below diagram FIXING TO TIMBER WALL PARAPET 1 Drill and install 4 four 14g x 75mm roofing screws recommended to pilot drill holes 2 Ensure ...

Страница 10: ...ALLATION MUST BE CARRIED OUT BY OR UNDER THE SUPERVISION OF A COMPETENT HEIGHT SAFETY INSTALLER ACCESS LAYOUT AND USE OF A SAFETYLINK ANCHOR SYSTEM SafetyLink anchor points are positioned by calculating the pendulum effect this limits the likelihood of a fall past the edge of the roof space The pendulum effect still applies to a flat roof SPACING MUST BE NO GREATER THAN THE RAFTER LENGTH PLEASE CO...

Страница 11: ...mplete access to your roof Detailed comprehensive documentation provided e g installation guides testing results product sheets should be provided SafetyLink can also provide you with a qualified and reputable installer of SafetyLink products Contact our design team at info safetylink com and we can plan your fall arrest system for you 2018 SafetyLink Pty Ltd Australia Patents SafetyLink Pty Ltd h...

Страница 12: ...1 4 2009 CLAUSE 9 5 EQUIPMENT WHICH HAS ARRESTED A FALL OR SHOWS A DEFECT Any piece of equipment including both personal and permanently installed items which has been used to arrest a fall or which shows any defect during operator or periodic inspection shall be withdrawn from service immediately and a replacement obtained if necessary A label indicating the condition or defect should be attached...

Отзывы: