TROUBLESHOOTING
11
PROBLEM
CAUSE
SOLUTION
Brazing pin does not ignite
or does not ignite long
enough.
Batteries not charged or are
defective.
Test batteries for proper charge.
Replace and/or
charge as necessary.
Blown fuse.
Check fuses.
Magnetic ground faulty.
Check that surface magnetic
ground is applied to is ground
clean. Check magnetic ground ca-
ble and plug for damage.
Faulty cables.
Check gun cables and plugs for
damage.
Bonding surface
contaminated.
Check that the brazing surface is
ground clean.
Braze is faulty.
Batteries not charged or are
defective.
Test batteries for proper charge.
Replace and/or charge as neces-
sary.
Incorrect PIN TYPE
setting.
Check PIN TYPE setting on the
control box.
Magnetic ground faulty.
Check that surface magnetic
ground is applied to is ground
clean.
Check magnetic ground cable and
plug for damage.
Bonding surface
contaminated.
Check that the brazing surface is
ground clean.
Incorrect grinding wheel is
used.
Use only Tyrolit grinding wheels or
carbide burr.
Ceramic ring was not
positioned square to the
lug.
Ensure ring is positioned
correctly.
Brazing pin not positioned
correctly in lug hole.
Ensure pin is positioned
correctly.