CHAPTER 2 Configure the Luna Appliance for your Network
Next, see
"Open a Connection" on page 30
.
Open a Connection
Perform your initial configuration via direct serial connection to the Luna appliance. Once network parameters are
established, you can switch to an SSH session over your network.
Direct administration connection via serial terminal is the method for initial configuration for the following reasons:
•
The specific IP address, randomly assigned to your Luna appliance by an automated testing harness during final
factory testing, is unknown.
•
Configuring network settings via SSH, in addition to requiring the original IP address, necessarily involves losing
that connection when a new IP is set.
•
A direct serial connection is the only route to log into the "recover" account, in case you ever lose the appliance's
admin password and need to reset. Therefore, you should verify, before you need it, that the connection works -
performing the appliance's network configuration is an ideal test.
•
Similarly, if you ever need to issue the
hsm factoryreset
command, you must be connected through a local
serial console for that command to be accepted.
To open a connection
1.
Connect a null-modem serial cable (supplied) between the serial port on the HSM appliance front panel and a dumb
terminal or a PC (for example a laptop) that will serve as the administration computer.
Note:
A standard null-modem serial cable with DB9 connectors is included with the HSM
appliance, as is a USB-to-serial adapter if needed. For security reasons, the USB port on the
Luna SA appliance recognizes only SafeNet HSMs and peripheral devices - therefore it is
prohibited from supporting general USB operations and thus does not accept a serial console
link; the 9-pin serial connector must be used.
2.
Use a terminal emulation package provided with your operating system. Set the Serial connection parameters:
–
Serial port baud rate: 115200
–
N,8,1 (no parity, 8 data-bits, one stop-bit)
–
VT-100 terminal emulation
–
hardware flow control selected.
3.
When the connection is made, the HSM appliance login prompt appears. [DEFAULTHOSTNAME]lunash:> The
[DEFAULTHOSTNAME] is replaced by the new hostname that you assign to your HSM appliance, later in these
instructions. The prompt changes the next time you start a secure command-line interface connection.
Note:
You might need to press [ENTER] several times to initiate the session.
You must
log in within two minutes
of opening an administration session, or the connection
will time out.
Now that you have established a connection, go immediately to the next page to log in as “admin” and begin configuring.
Next, see
"First Login & Changing Password" on page 31
.