Assembly instructions
Assembly instructions
Complete telephone assembly in the elevator car requires a space of
only 70X130mm for installation.
The alarm signal button can be changed between normally-open/
normally-closed.
It is possible to use the existing alarm button.
The telephone is using P100 or CPC protocol for communication with the
operator that receives the alarm.
P100 and CPC protocol is the most frequent alarm receiving system
used in Scandinavia, and it is also used in our own alarm receiver
equipment.
Check that the alarm-receiving operator has a receiver fi tted for P100/
CPC protocol voice call if you plan to use this protocol.
Hints:
When the alarm signal switch is activated
the telephone will call
up after 5 seconds of delay time. To do so, there must be a telephone
number programmed and a telephone line connected.
When the telephone starts calling, the connection sound is clearly heard
from the speaker.
Adjust the volume if needed with the volume control.
The fi rst two telephone numbers
(primary and secondary) are
pre-programmed for P100. There must be an 8-digits alarm code
programmed to make the P100 or CPC alarm work. The last two
telephone numbers (third and forth) are programmed for vocal
connection.
Vocal connection means a standard telephone call.
The receiving party does not have to do anything to get a vocal
connection, it is automatically done.