Self-Test Feature

How to Fix Your Unit:

If the “Self-Test” animation continues to occur on your device, STOP 

using your Compass. To resolve issue, please call Safeguard Equipment at 

1-(208)-773-9263 or email our team at [email protected]

COMPASS was designed with a built-in Self-Test function that ensures that every sensor is always operating 

properly. Every time the device is turned on and periodically while it’s in use, the COMPASS does a background 

test on its sensors to evaluate whether they are operating properly.

If an abnormality with one of the sensors is detected, COMPASS will respond by locking the unit out to all user 

operations. When this happens, the user is notified by the two corner lights changing to 

RED

 and 

YELLOW

, as 

shown in the image below.

On occasion, the unit’s Self-Test will lock out the device when it is first turned on. This most often happens when 

the unit is in the vicinity of a detectable electrical field. Even proximity to a computer or other such device can 

sometimes cause the COMPASS to lock the user out. If this happens, please see the instructions below on how to 

reset the device if this should happen.

1.  If a fault from the Self-Test is detected, Compass will lock out all user functions and provide a 

RED

 and 

YELLOW

 lights in the corners.

2.  Once locked out, the user should return to an area where there are no electrical sources present. It is 

important that the sensors are not detecting an electrical field when powering on.

3.  If Compass still fails to regain operations, then press and HOLD the center button for 10 seconds. At this 

point you should see the battery level animation. Once this animation is complete, your device will be reset.

4.  Upon resetting the Compass, the sensitivity of the device will be set to HIGH. This is the factory pre-set 

level. At this point the user can then manually adjust Compass to their desired sensitivity setting. This is 

discussed under “Master Sensitivity Settings.” Once the device has been reset, the Compass is free be utilized 

in normal operations.

5.  If Compass continues to provide the “Self-Test” lockout display, please stop using that device until a 

Safeguard representative has been contacted.

Содержание Compass

Страница 1: ...Always on Always safe Always aware User Guide Personal Voltage Current Detector...

Страница 2: ...around high voltage Overview Compass is a non contact high voltage detector that alerts users when they approach an electrified source Its advanced notification system is designed to warn the user of...

Страница 3: ...ields but will NOT fully block magnetic fields Conductors lying on the ground or very close to it will result in unsafe warning distances Electric fields will couple to the ground thus drastically red...

Страница 4: ...ugged from the charger Compass briefly displays the pre set sensitivity level before activating full function of the device Compass should be worn on the underside brim of the user s hard hat and with...

Страница 5: ...hes this level and will continue until battery is dead Master Sensitivity Settings FOR MANAGEMENT ONLY Plug device into the micro USB to begin charging then hold the center button for 5 seconds Red li...

Страница 6: ...hts indicating the adjustable AC VOLTAGE menu Once you are in this menu display quickly press the center button to change the device s sensitivity to Low 3 lights Medium 5 lights High 7 lights or Adap...

Страница 7: ...on or near the ground the warning distances will be dramatically reduced and can sometimes result in unsafe warning distances 20 ft 0 ft Busbar First Alert 12 ft Max Alert 6 ft 2 4 kV Proximity Alert...

Страница 8: ...vity level provided by Compass It is important to note that these established ranges fluctuate slightly due to a variety of work environment variables Potential variables include but are not limited t...

Страница 9: ...ectional notifications it s important to understand potential variables that could affect the accuracy of alerts Accuracy of directional alerts will be reduced when an overhead power system is above t...

Страница 10: ...t environment without the unit continuing to emit alerts If the user stays in place no further alerts will be emitted Should the user move closer to the threat the COMPASS will again initiate alerts A...

Страница 11: ...ed 2018 General Warning Distances 5 10 15 20 25 5 10 15 20 25 5 15 20 25 10 Side View First Alert Full Alert Sensitivity Setting HIGH Voltage 2 4 kV Sensitivity Setting HIGH Voltage 2 4 kV 0 0 5 5 10...

Страница 12: ...en proximity to a computer or other such device can sometimes cause the COMPASS to lock the user out If this happens please see the instructions below on how to reset the device if this should happen...

Страница 13: ...djustable Sensitivity Levels Low Medium High Adaptive Default Sensitivity Level High Operating Frequency 60 Hz Operating Voltages 2400 VAC Minimum to 35 4 kVAC RMS Line to Neutral Case Material Flame...

Страница 14: ...f life In the event that a Product cannot be repaired or replaced due to unavailability of parts Safeguard Equipment Inc will use commercially reasonable efforts to obtain substitute parts or conduct...

Страница 15: ...UIPMENT COM 208 773 9263 A Product of All rights reserved 2018 Contact Information www safeguardequipment com sales safeguardequipment com Phone 208 773 9263 Address 4442 West Riverbend Avenue Post Fa...

Отзывы: