Adaptive Mode

Adaptive: Important Notes

If the user is alerted and recognizes they are near an energized source - and does not require further alerts - the 

user can quickly press the center button to mute the notifications. This will be signaled by three decreasing tones 

and two 

RED

 lights. Compass then adjusts to the environment and will eliminate redundant alerts. If the user gets 

closer to the source, alerts will re-enable. If the user moves away from the source, Compass will regain its prior 

voltage sensitivity.

Quickly pressing the center button will revert Compass back to its full sensitivity and re-enable full intensity

notifications. This will be signaled by two increasing tones followed by corner 

GREEN

 lit LEDs.

How the Adaptive Setting Works:

NOTE: The alerts provided with the adaptive

setting will be those under the MEDIUM 

sensitivity.

The adaptive setting allows the user to

manually notify the C

OMPASS

 unit that the

user is aware of the threat in the area, but

they desire to work in that environment 

without the unit continuing to emit alerts.

If the user stays in place, no further alerts will

be emitted.

Should the user move closer to the threat, the

C

OMPASS

 will again initiate alerts.

As the user moves away from the working 

zone - and the threat - C

OMPASS

 will 

automatically adjust and will again issue 

alerts if the user once again gets closer to the

threat.

Once the user gets out of range of any

detected threats, the unit will automatically

revert to the the original notification ranges

found in the MEDIUM Sensitivity.

When using Compass in the Adaptive setting, it’s important to understand potential variables that could affect the 

accuracy of alerts.

•  Compass will operate at MEDIUM sensitivity when using adaptive sensitivity. 

•  If the user’s walking pace increases to a brisk walk, warning distances can experience a reduction of two (2) 

feet.

•  Compass warning distance will not be significantly affected due to different ground types such as soil, gravel, 

concrete, or wet surfaces unless ferrous material is encased in the soil.

•  Warning distances are reduced by conductive objects, such as a fence or vehicle. These objects attract the 

electric field of the nearby energized conductor.

•  Use of the Adaptive Sensitivity mode should be reserved for experienced professionals.

Содержание Compass

Страница 1: ...Always on Always safe Always aware User Guide Personal Voltage Current Detector...

Страница 2: ...around high voltage Overview Compass is a non contact high voltage detector that alerts users when they approach an electrified source Its advanced notification system is designed to warn the user of...

Страница 3: ...ields but will NOT fully block magnetic fields Conductors lying on the ground or very close to it will result in unsafe warning distances Electric fields will couple to the ground thus drastically red...

Страница 4: ...ugged from the charger Compass briefly displays the pre set sensitivity level before activating full function of the device Compass should be worn on the underside brim of the user s hard hat and with...

Страница 5: ...hes this level and will continue until battery is dead Master Sensitivity Settings FOR MANAGEMENT ONLY Plug device into the micro USB to begin charging then hold the center button for 5 seconds Red li...

Страница 6: ...hts indicating the adjustable AC VOLTAGE menu Once you are in this menu display quickly press the center button to change the device s sensitivity to Low 3 lights Medium 5 lights High 7 lights or Adap...

Страница 7: ...on or near the ground the warning distances will be dramatically reduced and can sometimes result in unsafe warning distances 20 ft 0 ft Busbar First Alert 12 ft Max Alert 6 ft 2 4 kV Proximity Alert...

Страница 8: ...vity level provided by Compass It is important to note that these established ranges fluctuate slightly due to a variety of work environment variables Potential variables include but are not limited t...

Страница 9: ...ectional notifications it s important to understand potential variables that could affect the accuracy of alerts Accuracy of directional alerts will be reduced when an overhead power system is above t...

Страница 10: ...t environment without the unit continuing to emit alerts If the user stays in place no further alerts will be emitted Should the user move closer to the threat the COMPASS will again initiate alerts A...

Страница 11: ...ed 2018 General Warning Distances 5 10 15 20 25 5 10 15 20 25 5 15 20 25 10 Side View First Alert Full Alert Sensitivity Setting HIGH Voltage 2 4 kV Sensitivity Setting HIGH Voltage 2 4 kV 0 0 5 5 10...

Страница 12: ...en proximity to a computer or other such device can sometimes cause the COMPASS to lock the user out If this happens please see the instructions below on how to reset the device if this should happen...

Страница 13: ...djustable Sensitivity Levels Low Medium High Adaptive Default Sensitivity Level High Operating Frequency 60 Hz Operating Voltages 2400 VAC Minimum to 35 4 kVAC RMS Line to Neutral Case Material Flame...

Страница 14: ...f life In the event that a Product cannot be repaired or replaced due to unavailability of parts Safeguard Equipment Inc will use commercially reasonable efforts to obtain substitute parts or conduct...

Страница 15: ...UIPMENT COM 208 773 9263 A Product of All rights reserved 2018 Contact Information www safeguardequipment com sales safeguardequipment com Phone 208 773 9263 Address 4442 West Riverbend Avenue Post Fa...

Отзывы: