SC-DTFPS   1050-60EO/I

 

Electrical

 

Input Voltage Taps (Vac)

 

230

±

15% EUROPE 

 

Input Frequency (Hz)

 

50/60

 

Input Current (A)

 

< 5.5A 

 

Input inrush current

 

< 10 A In single pulse of  5ms

 

Input Power Factor

 

0.95 at full load

 

Output Voltage Taps (Vac)

 

60, 66, 72V -25A     (87V -25A ) 

 

Total Output Current (A)

 

 25A  (15A max each port)

 

Short circuit time response (ms)

 

<10

 

Recovery safety time delay (sec)

 

> 3

 

Output Power (VA)

 

1050

 

Load Regulation (%)

 

< 2%

 

Output Protection Fuse

 

T15A

 

Efficiency (%)

 

95% at full load

 

Mechanical

 

Dimensions ( L , W , H ) mm

 

375 x 220 x 215

 

Weight (Kg/lbs)

 

20 kg

 

Housing Finish

 

White zinc / epoxy  plating 

 

Environment

 

Operating Temperature

 

-20ºC 

÷

 +60ºC

 

Storage Temperature

 

-20ºC 

÷

 +70ºC

 

Humidity

 

÷

 100% non condensing

 

Standard Features

 

Power Mains Cable

 

 

Mains Transients Protection

 

 

Quick Connection Output Coax socket

 

 

Output Fuse

 

 

Output Voltage Test Points

 

 

Output Current Measurement Loop

 

 

Power Indication Green LED

 

 

Optional Features

 

Output Screw Terminals

 

 

DC/AC  inverter for UPS

 

 

6

 

Содержание T-Former Series

Страница 1: ...Power Safecom T Former Series Stabilized pure sine voltage technology US Patent 8 415 822 Safecom TFPS Series Installation Manual FEB 2015 SAFECOM US Patent 8 415 822 1...

Страница 2: ...Page 7 Technology Page 8 Inside view Page 9 Voltage configuration Page 10 Bottom view Connecting panel Page 11 Back View bracket open Mounting template Page 12 back View bracket locked Page 13 Safeco...

Страница 3: ...ables almost unlimited lifetime No Noise No Vibration No environmental disturbance when installed on or near buildings Slow Start prevents fall of current breakers after power out or during ignition A...

Страница 4: ...mply with the electrical code should perform installation Before Installation Make sure that P S input voltage configuration matches the standard utility voltage level Make sure that P S output voltag...

Страница 5: ...s well as operational levels Thanks to its patent pending sine wave stabilizer technology the T Former s advanced electronic controller automatically monitors the line voltage and compensates for any...

Страница 6: ...tput Power VA 1050 Load Regulation 2 Output Protection Fuse T15A Efficiency 95 at full load Mechanical Dimensions L W H mm 375 x 220 x 215 Weight Kg lbs 20 kg Housing Finish White zinc epoxy plating E...

Страница 7: ...s the circuit breaker from falling during startup or utility power interruption The system also has electronic overload protection protecting the network and minimizing fuse blow when momentary short...

Страница 8: ...Inside view T former outdoor 87V 15A 8...

Страница 9: ...er to the network 1 Ensure utility power is OFF when changing voltage configuration at input output 2 Changing the settings is done by moving input output cables from one port to another The cable is...

Страница 10: ...Testing point Clamp Meter current test Power output Quick type RF connector Output indicator LED Green Red Ground Connector 10 Power output Quick type RF connector RF port IP monitoring External moni...

Страница 11: ...stalling on a wall use two 8 mm screws to fasten the bracket to the wall After bracket is fastened to the wall hang the PS on the bracket and tighten the screw at the bottom of the P S in order to loc...

Страница 12: ...Back view TF PS Bracket locked 12...

Страница 13: ...utdoor SC S TFPS 1300 90UI Single 60 75 87 15 110 120 45 65 Indoor SC STFPS 1300 90UO Single 60 75 87 15 110 120 45 65 Outdoor SC D TFPS 2200 90UI Dual 60 75 87 25 110 120 45 65 indoor SC D TFPS 2200...