Overview:  

T-Former  is  a  pure  stabilizer 

sine  wave  P.S  with    the

  highest-  efficiency,  and 

most reliable technology, specifically developed for the advanced operation of 
line amplifiers in CATV distribution systems. With about double the lifetime of 
legacy  Ferro-resonant  products,  it  delivers  at  least  5%  energy  savings 
compared  with  standard  systems.    Its  modular  optional  design  enables  an 
upgrade of the T-Former to UPS by adding a compatible ONLINE DC-AC inverter 
/Charger. This helps Operators  reduce  network expenditure  at capital, as  well 
as operational levels. 
 
  

 

 
Thanks  to  its  patent-pending 

sine  wave 

stabilizer  technology

,  the  T-Former's 

advanced 

electronic 

controller 

automatically  monitors  the  line  voltage 
and  compensates  for  any  changes, 
eliminating  negative  Inrush  current  side 
effects  resulting  from  utility  power 
recovery.  In  addition,  the  T-Former 
operates  in  complete  silence  -  solving 
noise  and  vibration  problems  inherent  in 
existing  products.  This  is  increasingly 
important  in  highly  populated  areas 
where  power  supply  devices  are  often 
mounted  near  buildings.    T-Former  is 
designed  to  work  at  a  wide  range  of 
temperatures  and  humidity  without 
maintenance, at full power capacity. 100% 
of  Safecom's  T-Formers  undergo  rigorous 
and repeated quality testing.  
  

 

5

 

Содержание T-Former Series

Страница 1: ...Power Safecom T Former Series Stabilized pure sine voltage technology US Patent 8 415 822 Safecom TFPS Series Installation Manual FEB 2015 SAFECOM US Patent 8 415 822 1...

Страница 2: ...Page 7 Technology Page 8 Inside view Page 9 Voltage configuration Page 10 Bottom view Connecting panel Page 11 Back View bracket open Mounting template Page 12 back View bracket locked Page 13 Safeco...

Страница 3: ...ables almost unlimited lifetime No Noise No Vibration No environmental disturbance when installed on or near buildings Slow Start prevents fall of current breakers after power out or during ignition A...

Страница 4: ...mply with the electrical code should perform installation Before Installation Make sure that P S input voltage configuration matches the standard utility voltage level Make sure that P S output voltag...

Страница 5: ...s well as operational levels Thanks to its patent pending sine wave stabilizer technology the T Former s advanced electronic controller automatically monitors the line voltage and compensates for any...

Страница 6: ...tput Power VA 1050 Load Regulation 2 Output Protection Fuse T15A Efficiency 95 at full load Mechanical Dimensions L W H mm 375 x 220 x 215 Weight Kg lbs 20 kg Housing Finish White zinc epoxy plating E...

Страница 7: ...s the circuit breaker from falling during startup or utility power interruption The system also has electronic overload protection protecting the network and minimizing fuse blow when momentary short...

Страница 8: ...Inside view T former outdoor 87V 15A 8...

Страница 9: ...er to the network 1 Ensure utility power is OFF when changing voltage configuration at input output 2 Changing the settings is done by moving input output cables from one port to another The cable is...

Страница 10: ...Testing point Clamp Meter current test Power output Quick type RF connector Output indicator LED Green Red Ground Connector 10 Power output Quick type RF connector RF port IP monitoring External moni...

Страница 11: ...stalling on a wall use two 8 mm screws to fasten the bracket to the wall After bracket is fastened to the wall hang the PS on the bracket and tighten the screw at the bottom of the P S in order to loc...

Страница 12: ...Back view TF PS Bracket locked 12...

Страница 13: ...utdoor SC S TFPS 1300 90UI Single 60 75 87 15 110 120 45 65 Indoor SC STFPS 1300 90UO Single 60 75 87 15 110 120 45 65 Outdoor SC D TFPS 2200 90UI Dual 60 75 87 25 110 120 45 65 indoor SC D TFPS 2200...

Страница 14: ...t quick type connectors without seizure screws Simply plug in connector at the front panel Connection is made quickly and reliably from outside Beryllium cooper contact 10 mm Note The center conductor...

Страница 15: ...the possible yet rare symptoms 15 Solution Reason Symptom The network must be monitored and the failure cause must be removed 1 P S was shut down due to overload current short circuit or a burnt fuse...