3 AppBlaster
D60829-07
17
2.6.3
SafeCom Color Front-ends
The SafeCom Color Front-end need to be opened and the Nuance Mx Proximity
Module inside need to be disconnected and connected temporarily with the
Nuance SafeCom cable “E33 USB Cable, 45 cm” (p/n SC0344020). Using the E33
cable’s male USB connector the module can now be connected directly to a
computer and be configured. After configurationat the original cable need to
be reconnected before the SafeCom Color Front-end is reassembled.
Warning:
Read (2.6.1) Electrostatic Discharge (ESD) Handling Procedures.
Failure to follow these procedures could lead to immediate, or longer term,
permanent failure and/or damage to the SafeCom Color Front-end – failures
and damage which is not covered by warranty.
1.
Place the SafeCom Color Front-end with top side down.
2.
Loosen the 6 screws at the bottom (type is Philips #2).
3.
Remove the bottom cover.
4.
Gently disconnect the cable (Red arrow 1 on the picture).
5.
Gently connect the Nuance SafeCom cable “E33 USB Cable, 45 cm” (p/n
SC0344020). The connector can fit one way only.
6.
Connect the E33 cable’s male USB connector to a computer to configure
it (3.5). When done configuring it proceed to assemble the SafeCom Color
Front-end.
7.
Gently disconnect the E33 cable from the module and connect the
original cable. The connector can fit one way only.
8.
Put the the bottom cover back on and mount it with the 6 screews.
9.
Connect the SafeCom Color Front-end to a SafeCom Controller and verify
that presenting a card results in the user holding the card is being
authenticated.
Note:
It is recommended to label the unit to track, that it has been modified.