A Safe Fleet Brand
4
Installation and Operation Manual
The Power-Fill foam refill systems provide for
the filling of the foam reservoirs on an apparatus
without manually filling the tanks from on top of the
apparatus. They are available as an on-board DC
powered system with automated panel control or
an off-board AC powered system with a manual
ON/OFF switch.
The DC Power-Fill system provides for an
automatic shut-off mode or a manual refill mode
via a panel-mounted control. Pushing the green
button will start the foam pump/motor in the
automatic refill mode. When the tank is full,
the green light will go on solid. To override the
automatic mode or to run in the manual mode,
push and hold the red button. To stop the
operation, release the red button. Caution must
be taken not to hold the red button too long or the
tank could overfill.
The AC Power-Fill system provides an AC driven
portable foam pump/motor assembly and a visual
interface typically mounted on the apparatus panel.
The foam pump/motor assembly is manually
switched on and off with a momentary on switch
mounted in the power cord. Switching on the pump
will start the refill process. When the tank is full,
an indicator light on the panel will illuminate. An
additional apparatus kit is available for fitting the
plumbing into other apparatus.
Both systems come with a placard, cam lock
fittings for the plumbing outside the apparatus,
foam pump/motor assembly, a refill wand with 6
feet of 1” ID suction hose, and a side-mount level
indicator switch.
2
A Quick Look at How the System Works
3
What You Get
Controller
Panel Placard
Flush Valve
Assembly with
Check Valve
Side-Mount
Level Sensor
Pump/Motor Assembly
Refill wand with 6 ft. suction
hose, cam lock fittings
and panel cap
Panel Check Valve
Flow Switch