The SAF FreeMile Series Full Outdoor Unit Technical Description and Configuration Guide • Rev. 1.3
© SAF Tehnika JSC 2012
20
2.2.8
Initial
configuration
with
Web
GUI
In
order
to
perform
initial
configuration
you
will
need
a
laptop
with
LAN
card,
2
Category
5e
Ethernet
cables
and
a
Power
over
Ethernet
injector.
Your
connected
laptop
should
be
in
the
same
subnet
with
manageable
SAF
FreeMile,
so
you
can
“see”
them;
that
is
why,
the
laptop
Ethernet
port
settings
should
be
set
as
follows:
(in
‘Microsoft
Windows’
go
to
Control
panel
Network
Connections
Local
Area
Connection
Properties
Internet
Protocol
(TCP/IP)
Properties
):
–
IP
address
192.168.205.1;
–
Net
mask
255.255.255.0;
–
everything
else
is
blank.
You
must
have
PoE
(Power
over
Ethernet)
injector
with
the
minimum
of
20W
power
supply
to
connect
the
laptop
to
the
SAF
FreeMile
FODU.
Power
over
Ethernet
injector
can
be
purchased
from
SAF
Tehnika
JSC
as
optional
accessory.
To
know
IP
address,
side
value
should
be
read
from
the
label.
See
Chapter
1.7
for
details.
–
If
Low
Side
‐
>
IP:
192.168.205.10
–
If
High
Side
‐
>
IP:
192.168.205.11
Connect
to
SAF
FreeMile
FODU
by
entering
IP
address
in
the
browser
address
line
‐
by
default
192.168.205.10
for
the
low
side
and
192.168.205.11
for
the
high
side.
(!)
Default
username
for
Web,
Telnet
and
FTP
access
is
admin
and
password
is
changeme.
It
is
recommended
to
use
the
following
or
later
versions
of
web
‐
browsers:
–
IE
v.
6.0
–
Mozilla
Firefox
v.
2.0.0.11
–
Safari
v.
3.0
–
Opera
v.
9.50
Initial
configuration
in
Web
GUI
should
be
done
individually
for
each
SAF
FreeMile
FODU.
STEP
1
First
step
is
to
choose
your
antenna
size
(30,
60
or
90
cm)
in
Main
page
„Radio
configuration”.
Press
„Apply”
button.
Note
that
“Apply
for
local
and
remote”
button
will
not
operate
until
microwave
link
is
established.
STEP
2
Run
„Spectrum
analysis”
while
second
unit
is
not
transmitting
in
order
to
check
availability
of
required
channel
as
well
as
overall
interference
STEP
3
Judging
upon
observed
interference,
choose
free
channel
in
30MHz
or
change
channel
bandwidth
to
10MHz
and
change
modem
configuration
if
required
.
STEP
4
Activate
Tx
power
by
choosing
Tx
power
value
in
Main
page
„Radio
configuration”
and
pressing
„Apply”
button.
STEP
5
All
configuration
steps
should
be
repeated
for
the
second
SAF
FreeMile
unit.
If
everything
was
configured
correct,
you
will
see
a
screen
similar
to
the
one
in
Figure
2.9.
(without
alarm
indications).
Содержание FreeMile Series
Страница 1: ...1 Technical Description and User Guide ...