DISPLAY OF THE MESSAGE E83
« Detection Process U max control »
Exceeded high threshold monitoring welding current user-defined
DISPLAY OF THE MESSAGE E84
« Detection Process Control Reel I min»
Exceeding low threshold current monitoring engine reeling user-defined
DISPLAY OF THE MESSAGE E85
« Detection Process Control Reel Imax»
Exceeded high threshold monitoring motor current reeling user-defined
DISPLAY OF THE MESSAGE E86 « absent Software »
Missing for a given device
please make an update generator software
DISPLAY OF THE MESSAGE « Error bus CAN »
Communication with a device is very disturbed. Check the connection of
the device.
It is imperative to connect and disconnect the device when the system is off