CORRECTIVE AND PREVENTIVE MAINTENANCE AND PRESERVATION

Attention 

Never wet the compressor or any of their parts. The cleaning of outside surfaces should 

be performed weekly with a duster or soft cloth slightly moistened with water; the use of

other products may damage the compressor finish or plastic parts. Be sure to thoroughly

clean the head’s upper part, responsible for its cooling. The accumulated dust affects the

heat dissipation.

Cleaning

Important: In order to execute cleaning or any type of maintenance, ensure that the equipment is

disconnected from the electrical network.

Additional procedures for reuse

The equipment can be reused in undetermined, i.e. unlimited, quantities, only needing to be cleaned

and disinfected.

Preventive Maintenance

The equipment should be calibrated routinely, as per the legislation in force in the country.

But never with a period exceeding 3 years.

In order to protect your equipment, seek Alliage technical assistance for periodic revisions of 

preventive maintenance.

Filter Change:

Keep the air filter(s) clean and in good condition of usage. The air filter prevents dust from entering

into the compressor and reduces the operating noise.

Over time, the filter will become dirty, reducing the air inlet flow and causing the decrease of 

compressor  performance.  The  filter  should  be  replaced  every  3  months  on  average  or  before, 

depending  on  the  air  quality.  Additional  filters  are  available  for  purchase  through  the  Alliage 

Technical Assistance network.

To perform the change, open the filter enclosure by turning the metal cover; remove the old filter and

insert the new one; put the cover again by turning it in the opposite direction.

Содержание 40L

Страница 1: ......

Страница 2: ...ni industrial LTDA C N P J 59 064 766 0001 82 Avenida Professora Luiza Garcia Ribeiro 130 Santa Rosa de Viterbo SP Brasil For improved safety Read and understand all the instructions contained in the...

Страница 3: ...arnings during the installation of the equipment 17 Recommendations for preserving the equipment 17 Precautions and warnings during the use of equipment 18 Precautions and warnings after the use of eq...

Страница 4: ...pment is for dental use use only It must be operated and utilized by specialized professional certified professional according to the legislation of the country and following the instructions of the m...

Страница 5: ...ate the equipment s operation and maintenance Safety System with valve that starts running for pressure release if there is any failure from the pressure switch and overload shield in order to protect...

Страница 6: ...gine 05 On off switch 06 Inner pressure gauge manometer 07 Safety valve 08 Overload protector 09 Register of the outlet pressure 10 Manometer of the outlet pressure 11 Outflow rate register 12 Drainag...

Страница 7: ...ral features Supply voltage and frequency 40 and 65 Liters 220V 10 60Hz or 127V 10 60Hz Supply voltage and frequency 150 Liters 220V 10 60Hz Rated current 40L 127V 13 A 40L 220V 6 7 A 65L 127V 13 A 65...

Страница 8: ...cfm 65l 283 l min 10 cfm 150l 566 l min 20 cfm Max pressure 40l 120 psi 8 3 bar 65l 120 psi 8 3 bar 150l 120 psi 8 3 bar Number of Cylinders 40l 2 65l 2 150l 2x2 Other specifications Head weight 40L...

Страница 9: ...9 Dimensions 40 LITERS TECHNICAL SPECIFICATIONS...

Страница 10: ...10 Dimensions 65 LITERS TECHNICAL SPECIFICATIONS...

Страница 11: ...11 Dimensions 150 LITERS TECHNICAL SPECIFICATIONS...

Страница 12: ...ay from direct sun light exposure Packing to be transported and or stored with care should not suffer drop and neither receive impact Temperature limit for the packing to be stored or transported Turn...

Страница 13: ...ute this task Alliage bears no responsibility for damages or accidents caused by poor installation executed by a technician not authorized by Alliage Only after the equipment has been installed and du...

Страница 14: ...2 psi and so successively and automatically If the pressure switch fails the safety valve 07 will start running by releasing the excessive pressure Voltage Rated current Circuit breaker 127V 10 13 A 1...

Страница 15: ...sal Open the register slowly until all the accumulated water is drained and air starts to flow again Close the register firmly so that no leakage can occur Compressed air outlet The air pressure on th...

Страница 16: ...hPa to 1060 hPa 525 mmHg to 795 mmHg Operation altitude 2000m Attention The Equipment maintains its condition of safety and efficacy provided that it is maintained stored as mentioned in this instruct...

Страница 17: ...apacity while using it does not exceed their technical specifications Alliage assumes no liability for damages accidents resulting from improper use or non compliance with the instructions described i...

Страница 18: ...islation of the country Pay attention to the local legislation of the country for the conditions of installation and disposal of residue Precautions to be adopted against foreseeable or uncommon risks...

Страница 19: ...eventive Maintenance The equipment should be calibrated routinely as per the legislation in force in the country But never with a period exceeding 3 years In order to protect your equipment seek Allia...

Страница 20: ...rective Maintenance Alliage states that the supplying of the circuits diagram Part lists or any other information that permits the technical assistance by the user can be requested since previously ag...

Страница 21: ...an the specified Connect the compressor to the correct network Wait for the regularization of network The compressor does not re aches the maximum pressure lesser efficiency works for a short period o...

Страница 22: ...resentative We call your attention to our authorized resellers chain Only this chain will keep your equipment constantly new because it has trained technical assistant and specific tools for the corre...

Страница 23: ...23...

Страница 24: ......

Отзывы: