Drainage
Drainage of the air tank should be performed to eliminate the condensed water accumulation
inside the tank. The drainage frequency depends on environmental conditions and operating time,
on average the drainage is recommended to be done on a daily basis.
To perform the drainage, insert the hose which is connected to the register (13) located underneath
the tank inside a container for water disposal. Open the register slowly until all the accumulated
water is drained and air starts to flow again. Close the register firmly so that no leakage can occur.
Compressed air outlet
The air pressure on the outlet can be adjusted through the register
(09), check the setting on the pressure gauge (10).
The air outflow rate can also be adjusted in the register (12).
In tandem with the pressure and flow rate registers, there is a filter
that removes moisture and impurities remaining in the air, the moisture
that is removed from the outlet will get stored in the reservoir (11),
to empty it press the pin underneath the reservoir.