Turning on the Compressor
Turn the power switch (05) to turn on the Compressor. The compressor will be turned on until the
inner pressure of the tank displayed on the gauge (06) reachs 8.16 kgf / cm ² (0.8 MPa - 116 psi), on
this value the pressure switch will turn off the compressor which will be powered again when the
inner pressure reaches of 5.71 Kgf/cm ² (0.56 MPa - 81,22 psi), and so successively and automatically.
If the pressure switch fails, the safety valve (07) will start running by releasing the excessive pressure.
Voltage
Rated current
Circuit breaker
127V~ ±10%
13 A
16 A
220V~ ±10%
6,7 A
10 A
40L
65L
Wiring Diameter (tread):
For distance up to 5m from the circuit breaker until equipment socket, wiring
should be 2,5 mm ² section; from 5 to 15m, 4mm wiring; from 15 to 50m, 6mm wiring (According to
standard ABNT NBR-0148, metric series PVC 70 °C).
Voltage
Rated current
Circuit breaker
127V~ ±10%
13 A
16 A
220V~ ±10%
6,7 A
10 A
06 05
07
150L
Voltage
Rated current
Circuit breaker
220V~ ±10%
13,4 A
16 A