6 - 2
6
USE OF THE MACHINE
166.07
.A02
Revision 00 Date 18.10.1998
6.1.1
SWITCHBOARD
(References in figures 6.1 and 6.1.1)
The switchboard includes a power section that contains all the parts used to drive the utilities (contactors, relays, etc.)
and a logic section with the devices that process the signals transmitted from the keyboard and controls located on the
machine.
A control keyboard, found on the logic section, is used by the operator to run and monitor the machine. A programmable
logic controller is used and the work-cycle can be set from the keyboard. Fault messages and the most significant stages
of the work-cycle are shown on the display.
E0004P
WARNING!
Button SB31, which enables operation, must be pressed whenever the start button is pressed.
All the information concerning use of the switchboard is given in the Instructions B Manual,
Use of the Microprocessor Based Control System.
TOP DISPLAY
(See figure 6.1.1)
The top display (3) is provided in a number of versions, depending on the type of caps handled.
AP2
Temperature control, Tool heating (optional)
AP3
Temperature control, Tool cooling (optional)
PC1
Electronic counter for exiting caps (detected by SQ11) (optional)
PC2
Electronic counter for caps rejected by FDP (only if FDP is provided)
SA1
Machine ON - OFF selector switch
SA18
Tool heating ON-OFF selector switch
SA30
LOCAL - OFF - REMOTE selector switch
SA40
Cap discharge control ON - OFF selector switch
SA100
MANUAL - OFF - AUTOMATIC mode selector switch
SB6A
Motor M6 stop button (manual mode)
SB6M
Motor M6 start button (manual mode)
SB7
Motor M7 start / stop button (manual mode)
SB8A
Motor M8 stop button (manual mode)
SB8M
Motor M8 start button (manual mode)
SB11
Motor M11 start / stop button (manual mode)
SB22
Motor M22 start / stop button (manual mode)
SB30A
Automatic cycle stop button (machine in local)
SB30M
Automatic cycle start button (effective with machine in automatic and local, button SB31 must be pressed at
the same time)
SB31
Keyboard enable button
SB33A
Motor M33 stop button (manual mode)
SB33M
Motor M33 start button (manual mode)
SB100
Emergency stop button on switchboard
SB101
Reset button (shutdown conditions)
SB102
Reset button PC1 (only with cap counter)
SB103
Button for changing boxes (only with cap counter)
Содержание BTA 900
Страница 2: ...0 2 TABLE OF CONTENTS 166 07 A02 Revision 00 Date 18 10 1998...
Страница 4: ...0 4 TABLE OF CONTENTS 166 07 A02 Revision 00 Date 18 10 1998...
Страница 10: ...1 4 1 GENERAL INFORMATION 166 07 A02 Revision 00 Date 18 10 1998...
Страница 44: ...3 10 3 SAFETY EQUIPMENT AND PRECAUTIONS 166 07 A02 Revision 00 Date 18 10 1998...
Страница 80: ...7 22 7 ADJUSTMENTS 166 07 A02 Revision 00 Date 18 10 1998...
Страница 88: ...9 2 9 DISMANTLING 166 07 A02 Revision 00 Date 18 10 1998...