SOUTHERN AVIONICS COMPANY
SE Series Installation and Setup
7-15
Operational Checks
7.19.4
Press
SPCL FCTN +6
again to test the TX2 IDENT.
7.19.5
Verify that within 60 seconds the system shuts down TX2 and enters the failed state illuminating
the FAIL LED. The LCD should indicate TX2 has shut down due to an IDENT fault.
7.19.6
Press RESET to return to normal operation.
7.19.7
This concludes SE Series Dual Transmitter Operational Checks using Front Panel Controls.