145
Energy Smart |
In Compliance with EU 1254/14 - Annex IV
TABLE OF COMPLIANCE WITH REGULATIONS EU 1253/14
AND EU 1254/14
Table of compliance with Regulation EU 1254/14 Annex IV - Energy Smart
Supplier name or brand
Sabiana SpA
Supplier model identification
ENY-SHP-150
ENY-SHP-170
ENY-SHP-270
Specific energy consumption SEC
in [kWh/(m²a)] for each applicable
climate zone (temperate, hot, cold,
climate)
-39,9
-15,4
-78,0
-42,05
-16,8
-81,5
-38,9
-14,8
-76,4
SEC class - temperate climatic zone
A
A+
A
Type declared according to EU
1253/14
BVU
BVU
UVB
Type of drive installed
Continuous speed variator
Continuous speed variator
Continuous speed variator
Type of heat recovery system
Static sensitive heat recovery unit
Static sensitive heat recovery unit
Static sensitive heat recovery unit
Thermal efficiency
87,0%
92,1%
84,4%
Maximum flow rate [m³/h]
3
150
170
270
Power absorbed by the fan drive,
including all motor control devices,
at maximum flow rate [W]
4
59
50
105
Sound power level (LWA) in [dB(A)]
38,0
44,9
41,3
Reference flow rate [m³/h]
105
120
190
Reference pressure difference [Pa]
50
50
50
SPI [W/(m³/h)]
0,227
0,193
0,240
Control factor and type of control
0,85
Centralised ambient control with
humidity sensor
0,85
Centralised ambient control with
humidity sensor
0,85
Centralised ambient control with
humidity sensor
Maximum percentages declared [%]
of internal and external leakage
Internal leakage: 1,8%
Internal leakage: 0,5%
Internal leakage: 0,4%
External leakage: 0,8%
External leakage: 2,3%
External leakage: 1,1%
Position and description of the visual
warning signal relating to the filter
for RVUs intended for use with filters,
including a text that emphasizes the
importance of replacing the filter at
regular intervals in order to safeguard
unit performance and energy
efficiency
Please refer to the following parts of the brochure:
• T-EP control description
• Recommendations for filter replacement:
filters clogging could result into relevant flow rate reduction, which
implies the need of frequent windows opening and consequent thermal demand increase.
• Proper replacement period depends on background air quality, which can broadly vary between city centers
and countryside.
• In order to prevent filters clogging, optimum average period for filters replacement is 3 month. However, due
to normal dust collection and spring pollens, maximum suggested period should not exceed 6 months.
• Filters replacement period can be modified by maintainer with a precision of days (min 30, max 360)
Internet address with the disassembly
instructions
www.sabiana.it
www.sabiana.it
www.sabiana.it
AEC (Annual Energy Consumption)
[kWh/a]
250
205
787
220
175
757
262
217
799
AHS (Annual Heating Energy Savings)
[kWh/a]
4548
2057
8898
4690
2120
9170
4478
2025
8760
Содержание ENY-SP-180
Страница 2: ...Energy Smart...
Страница 4: ...Energy Smart 2...
Страница 17: ...15 Energy Smart...
Страница 25: ...23 Energy Smart Vertical Version ENY SP and ENY S Versions 12 5 4 3 2 1 11 10 9 8 7 6...
Страница 45: ...43 Energy Smart Horizontal Version Pro ENY SHP 150 Version 3 1 2 7 9 11 10 4 6 8 5...
Страница 47: ...45 Energy Smart Horizontal Version Pro ENY SHP 170 Version 1 2 3 5 4 3 7 10 9 11 5 6 8...
Страница 49: ...47 Energy Smart Horizontal Version Pro ENY SHP 270 Version 1 2 3 4 7 10 9 11 5 6 8...