Energy Smart |
Table of compliance with Regulations EU 1254/14 Annex IV - Energy Smart
Supplier name or brand
Sabiana SpA
Supplier model identification
ENY-SP-180
ENY-SP-280
ENY-SP-370
ENY-SP-460
ENY-SP-600
Specific energy consumption SEC
in [kWh/(m²a)] for each applicable
climate zone (temperate, hot, cold,
climate)
-42,32 -17,2 -81,6 -42,29 -17,2 -81,6 -42,47 -17,2 -82,0 -40,10 -15,4 -78,6 -39,71 -15,1 -78,1
SEC class - temperate climatic zone
A+
A+
A+
A
A
Type declared according to EU
1253/14
BVU
BVU
BVU
BVU
BVU
Type of drive installed
Continuous speed
variator
Continuous speed
variator
Continuous speed
variator
Continuous speed
variator
Continuous speed
variator
Type of heat recovery system
Static sensitive heat
recovery unit
Static sensitive heat
recovery unit
Static sensitive heat
recovery unit
Static sensitive heat
recovery unit
Static sensitive heat
recovery unit
Thermal efficiency
91,5%
91,4%
92,5%
88,6%
88,0%
Maximum flow rate [m³/h]
3
180
280
370
460
600
Power absorbed by the fan drive,
including all motor control devices,
at maximum flow rate [W]
4
50
70
120
215
300
Sound power level (LWA) in [dB(A)]
38,9
43,1
46,3
47,9
52,4
Reference flow rate [m³/h]
130
200
260
320
420
Reference pressure difference [Pa]
50
50
50
50
50
SPI [W/(m³/h)]
0,174
0,174
0,179
0,237
0,247
Control factor and type of control
0,85
Centralised
ambient control
with humidity
sensor
0,85
Centralised
ambient control
with humidity
sensor
0,85
Centralised
ambient control
with humidity
sensor
0,85
Centralised
ambient control
with humidity
sensor
0,85
Centralised
ambient control
with humidity
sensor
Maximum percentages declared [%]
of internal and external leakage
Internal leakage:
1,2%
Internal leakage:
0,7%
Internal leakage:
0,5%
Internal leakage:
0,3%
Internal leakage:
0,6%
External leakage:
1,7%
External leakage:
1,0%
External leakage:
0,8%
External leakage:
0,7%
External leakage:
1,84%
Position and description of the visual
warning signal relating to the filter
for RVUs intended for use with filters,
including a text that emphasizes the
importance of replacing the filter at
regular intervals in order to safeguard
unit performance and energy
efficiency
Please refer to the following parts of the brochure:
• T-EP control description
• Recommendations for filter replacement: filters clogging could result into relevant flow rate reduction,
which implies the need of frequent windows opening and consequent thermal demand increase.
• Proper replacement period depends on background air quality, which can broadly vary between city centers
and countryside.
• In order to prevent filters clogging, optimum average period for filters replacement is 3 month. However,
due to normal dust collection and spring pollens, maximum suggested period should not exceed 6 months.
• Filters replacement period can be modified by maintainer with a precision of days (min 30, max 360).
Internet address with the disassembly
instructions
www.sabiana.it
www.sabiana.it
www.sabiana.it
www.sabiana.it
www.sabiana.it
AEC (Annual Energy Consumption)
[kWh/a]
203
158
740
203
158
740
207
162
744
260
215
797
269
224
806
AHS (Annual Heating Energy Savings)
[kWh/a]
4670 2111 9136 4667 2110 9131 4697 2124 9189 4591 2076 8982 4576 2069 8951
In Compliance with EU 1254/14 - Annex IV
TABLE OF COMPLIANCE WITH REGULATIONS EU 1253/14
AND EU 1254/14
Содержание ENY-SP-180
Страница 2: ...Energy Smart...
Страница 4: ...Energy Smart 2...
Страница 17: ...15 Energy Smart...
Страница 25: ...23 Energy Smart Vertical Version ENY SP and ENY S Versions 12 5 4 3 2 1 11 10 9 8 7 6...
Страница 45: ...43 Energy Smart Horizontal Version Pro ENY SHP 150 Version 3 1 2 7 9 11 10 4 6 8 5...
Страница 47: ...45 Energy Smart Horizontal Version Pro ENY SHP 170 Version 1 2 3 5 4 3 7 10 9 11 5 6 8...
Страница 49: ...47 Energy Smart Horizontal Version Pro ENY SHP 270 Version 1 2 3 4 7 10 9 11 5 6 8...