DIGITAL TRANSDUCER
Configuration and CAN Interface
PRELIMINARY
CANopen
PCS III Technical Description CANopen 1r1 UK 310715.docx
09/02/2021
S2Tech srl
37
/
58
17.3.
Communication Profile (Tables)
Index
Sub-
index
Name
Type
Attri-
bute
Default-
value
Meaning
0x1000 0
Device Type
UI32
ro
Value per
DS301
0x1001 0
Error Register
UI8
ro
0
TBD
0x1003 0
1
...
10H
Predefined error
field
Error array
UI8
UI32
UI32
ro
ro
ro
0
no
no
TBD
Number of different errors which occurred
A maximum of 16 different errors are managed.
0x1005 0
COB ID Sync
messg.
UI32
rw
80H
COB-ID of the SYNC object
0x1008 0
Manufacturer
Device Name
VS
ro
01-48
S2Tech
Device name of the communication module
0x1009 0
Manufacturer
Hardware Version
VS
ro
1.00
Hardware version number
0x100A 0
Manufacturer
Software Version
VS
ro
1.01
Software version number
0x100C 0
Guard Time
Cycle time for node
monitoring
UI16
rw
0
Cycle time in ms, set by the NMT Master or the configuration tool.
0x100D 0
Life Time Factor
Wait time if no
guarding
UI8
rw
0
Wait time is set by the NMT Master or the configuration tool.