4
I M P O R T A N T S A F E T Y I N F O R M A T I O N
Basic safety precautions should be observed when operating the PT-6002 product and other
associated equipment.
1. A qualified electrician must install the PT-6002 in accordance to the National and Local Electrical Codes.
2. The PT-6002 must not be less than 5 feet (3 meters in Canada) from inside edge of pool. ONLY USE
COPPER CONDUCTORS.
3. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying
capacity of conductors.
4. For the bonding, grounding, installing, and wiring of underwater lights to the PT-6002 refer to Article
680 of the National Electrical Code or Article 68 of the Canadian Electrical Code.
5. This device should never operate equipment that could cause property damage, bodily injury, or death
should it be activated unexpectedly.
6. Never allow children to operate the PT-6002 unsupervised.
F C C W A R N I N G
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
2. Changes or modifications not expressly approved by S.R Smith. could void the user’s authority to
operate the equipment.
ELECTRICAL SHOCK HAZARD – SWITCH DOES NOT TURN OFF INPUT POWER.
Failure to disconnect input power before servicing can lead to serious injury, or death.
Disconnect input power before servicing.
Replace all parts and panels before reconnecting power and operating
DANGER – FAILURE TO FOLLOW THESE WARNINGS, INSTRUCTIONS, AND THE
OWNER’S MANUAL MAY RESULT IN SERIOUS INJURY OR DEATH.
ELECTRICAL RATINGS
Do not exceed the maximum electrical ratings of the PT-6002. Install a 5A 120VAC GCFI
Circuit Breaker for PT-6002 Input. The PT-6002 Low Voltage lighting circuits are rated for 5A,
12 or 13VAC, 60W Max. per circuit.
Содержание Power Tower PT-6002