background image

 

7

 
As an AquaBlast

TM

 & RocketRide

TM

 FunSlide

TM

 owner, it is your responsibility to explain 

the nature of this danger to all persons who may use your AquaBlast

TM

 & RocketRide

TM

 

FunSlide

TM

, since they may not otherwise appreciate the dangers of performing head 

first slides. 
 

 

DAILY/WEEKLY MAINTENANCE OF THE AquaBlast

TM

/RocketRide

TM

 

FUNSLIDE

TM

 

 

1.  When hosing down the deck, hose your AquaBlast

TM

 & RocketRide

TM

 FunSlide

TM

  

to wash away any dust, dirt or other debris, which may have accumulated. 

2.  Be sure that water fittings are not leaking, and clean spray nozzles periodically to 

permit water to be sprayed on the slide runway. 

3.  All anodized aluminum parts require little maintenance.  Hose and wipe to clean. 
4.  While cleaning aluminum parts, check and see that all nuts and bolts are tight 

and secure. 

5. The 

INTENDED USE LABELS

 shall be maintained on the ladder and the transom of 

the slide entrance as indicated to the right.  If they become faded or un readable 
they should be replaced.  Additional labels are available from S.R. Smith upon 
request.  (see FIGURE S). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

DO NOT SLIDE HEAD FIRST

FIGURE R 

250 LBS. WEIGHT LIMIT

LOOKOUT FOR PEOPLE AND OBJECTS BELOW

SLIDE FEET & ARMS FIRST

IN SEATED POSITION

ONLY ONE PERSON AT A TIME

CAUTION

WARNING

CORRECT

SITTING SLIDE

FIGURE S 

Содержание AQUABLAST

Страница 1: ...MANUFACTURING PLANT Portland Tennessee www srsmith com 06 692 S R SMITH LLC 2005 DEC 05 C A U T I O N S R SMITH AquaBlastTM RocketRideTM FUNSLIDESTM ARE MANUFACTURED FOR INSTALLATION AND USE ON RESID...

Страница 2: ...ls houseboats boat docks floating docks or platforms APPLICABLE STANDARDS AND CODES 1 All S R Smith AquaBlastTM RocketRideTM FunSlidesTM are manufactured in accordance with Consumer Products Safety Co...

Страница 3: ...E M D A minimum depth of four feet six inches 4 6 shall be maintained at a distance of nine feet 9 along the extended centerline of the slide from Pt A see FIGURE M 2 A minimum clearance area in front...

Страница 4: ...or diving board may intersect each other provided that they are not used simultaneously CHART 1 BOARD MINIMUM CLEARANCE AREA POOL TYPE C DIMENSION W DIMENSION I 14 6 5 0 II 14 6 6 0 III 16 6 6 0 IV 18...

Страница 5: ...t of the slide runway exit above the water 20 max Measure the distance between the slide centerline and the edge of other pool equipment 7 Observe the position of the exit of the slide as shown in FIG...

Страница 6: ...chances Have the slide inspected and if necessary repaired by a competent professional who is familiar with acrylic water slides before using the AquaBlastTM RocketRideTM water slide again See INSTAL...

Страница 7: ...g and clean spray nozzles periodically to permit water to be sprayed on the slide runway 3 All anodized aluminum parts require little maintenance Hose and wipe to clean 4 While cleaning aluminum parts...

Страница 8: ...bfree Tackle Spic and Span Powder Calgon Bath Topjob Clorox Bleach Glass Plus Tilex Always read the label instructions on any cleaner carefully before applying it to a Plexiglas DR acrylic surface AVO...