background image

 

3

MANUFACTURER’S PLACEMENT INSTRUCTIONS

 

 
 

The AquaBlast

TM

 & RocketRide

TM

 FunSlides

TM

 

owner must confirm that the 

Manufacturer’s Placement Instructions have been followed by the Installer. 

 
 

1.  The critical dimensions for placement of the slide are as shown in FIGURES M and N. 

 

 

A.  The slide exit runway surface shall not exceed twenty inches (20”) above the 

water surface and not less than eight inches (8”) above the deck/coping surface 
(see Figure I). 

B.  The slide shall be positioned so that all water flowing off the runway exit drops 

into the pool. 

C.  The minimum depth of water below the exit lip of the slide shall be three feet (3’) 

and increases to four feet six inches (4’-6”) at Pt.A which is a distance of four feet 
six inches (4’-6”) from the exit lip of the slide.  (see FIGURE M). 

D.  A minimum depth of four feet six inches (4’-6”) shall be maintained at a distance 

of nine feet (9’) along the extended centerline of the slide from Pt.A. (see 
FIGURE M). 

 
2.  A minimum clearance area in front of the slide shall be 
maintained away from the coping, another slide, a diving 
board or a rope and float line.  (see FIGURE P) 
 

A.  The minimum clearance distance on either side of the 

extended centerline of the slide runway shall not be 
less than three feet six inches (3’-6”) at a point no 
less than two feet six inches (2’-6”) from the exit of 
the slide and extending a distance of thirteen feet six 
inches (13’-6”) in front of the slide.  (see FIGURE N) 

 

B.  The minimum clearance area in front of a diving 

board is a minimum distance of three feet six inches 
(3’-6”) on either side of the board’s centerline.  Pt.C 
extends a minimum distance of “C” from the tip end of 
the board.  The width distance “W” on either side of Pt.C is given in CHART 1 
and shown in FIGURE O. 

 

FIGURE M 

FIGURE N 

Содержание AQUABLAST

Страница 1: ...MANUFACTURING PLANT Portland Tennessee www srsmith com 06 692 S R SMITH LLC 2005 DEC 05 C A U T I O N S R SMITH AquaBlastTM RocketRideTM FUNSLIDESTM ARE MANUFACTURED FOR INSTALLATION AND USE ON RESID...

Страница 2: ...ls houseboats boat docks floating docks or platforms APPLICABLE STANDARDS AND CODES 1 All S R Smith AquaBlastTM RocketRideTM FunSlidesTM are manufactured in accordance with Consumer Products Safety Co...

Страница 3: ...E M D A minimum depth of four feet six inches 4 6 shall be maintained at a distance of nine feet 9 along the extended centerline of the slide from Pt A see FIGURE M 2 A minimum clearance area in front...

Страница 4: ...or diving board may intersect each other provided that they are not used simultaneously CHART 1 BOARD MINIMUM CLEARANCE AREA POOL TYPE C DIMENSION W DIMENSION I 14 6 5 0 II 14 6 6 0 III 16 6 6 0 IV 18...

Страница 5: ...t of the slide runway exit above the water 20 max Measure the distance between the slide centerline and the edge of other pool equipment 7 Observe the position of the exit of the slide as shown in FIG...

Страница 6: ...chances Have the slide inspected and if necessary repaired by a competent professional who is familiar with acrylic water slides before using the AquaBlastTM RocketRideTM water slide again See INSTAL...

Страница 7: ...g and clean spray nozzles periodically to permit water to be sprayed on the slide runway 3 All anodized aluminum parts require little maintenance Hose and wipe to clean 4 While cleaning aluminum parts...

Страница 8: ...bfree Tackle Spic and Span Powder Calgon Bath Topjob Clorox Bleach Glass Plus Tilex Always read the label instructions on any cleaner carefully before applying it to a Plexiglas DR acrylic surface AVO...

Отзывы: