Page 15 — English
STARTING THE ENGINE
See Figures 13 - 16.
NOTICE
:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
NOTE
: If location of generator is not level, the unit may not
start or may shut down during operation.
Unplug all loads from the generator.
Turn the fuel valve to the
ON (I)
position.
Pull the choke out to the
START
position.
NOTE
: If engine is warm or the temperature is above
50˚F, push the choke in to the
RUN
position.
Start the engine.
1
Put the engine switch in the
ON
position.
2
Slide down and hold the lock button while pushing
the engine switch to the
START
position. Release the
switch when the engine starts.
NOTE:
The battery may require charging before the gen-
erator can be started using only the engine switch. The
generator can be started by pulling the recoil starter grip.
Once the generator is started, the battery will charge as
the unit runs. To start the engine using the recoil starter:
1
Put the engine switch in the
ON
position.
2
Pull the recoil starter grip until the engine runs.
NOTE:
Do not allow the grip to snap back after starting;
return it gently to its original place.
Allow the engine to run for 15-30 seconds, then move
the choke to the
RUN
position.
STOPPING THE ENGINE
See Figures 14 and 16.
To stop the engine under normal operating conditions:
Remove any load from the generator.
Turn the fuel valve to the
OFF (O)
position.
Push in at the bottom of the switch to place the engine
switch in the
OFF
( O )
position.
To stop the engine in an emergency situation:
Push in at the bottom of the switch to place the engine
switch in the
OFF
( O )
position.
WARNING:
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of “cool down” time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
OPERATION
MAINTENANCE
Normal maintenance, replacement or repair of emission con-
trol devices and systems may be performed by any qualified
repair establishment or individual with original or equivalent
parts. Warranty and recall repairs must be performed by an
authorized service center; please contact customer service
for assistance.
WARNING:
Before inspecting, cleaning, or servicing the machine,
shut off engine, wait for all moving parts to stop, and
disconnect spark plug wire and move it away from spark
plug. Allow 30 minutes of cool down time before perform-
ing any maintenance. Failure to follow these instructions
can result in serious personal injury or property damage.
WARNING:
When servicing, use only recommended or equivalent
replacement parts. Service or maintenance performed
by unqualified personnel or use of any other parts could
result in a personal injury hazard or property damage.
NOTICE:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts,
caps, etc. Tighten securely all fasteners and caps and
do not operate this product until all missing or damaged
parts are replaced. Please contact customer service or
a qualifed service center for assistance.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water en-
tering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
Содержание RY907000
Страница 25: ...Page 21 English NOTES ...
Страница 46: ...Page 22 Français NOTES ...
Страница 67: ...Pàgina 22 Español NOTAS ...