System Navigation: 

The Toolbar 

INSPEX II toolbar icons (Fig 3): 

 

Zoom in 

Zoom out

 

Toggle between live and static image

 

Take snapshot of a live image

 

Auto Focus

 

Camera Overview

 

Settings

 

Save File

 

Open File

 

Overlay

 

Measurement

 

Image Stacking

 

Log On/Off

 

Note:

 The toolbar can be hidden by selecting 'AutoHide 

Main Toolbar' from the System Settings. (Page 13)

 

  

Fig 3. 

Содержание Ash INSPEX II

Страница 1: ......

Страница 2: ...ial Start up 9 System Navigation 10 The Toolbar 10 Toolbar Icons Explained 11 Toggle 11 Snapshot 11 Autofocus 11 Settings 12 Camera 12 Lighting Control 13 System Settings 13 Network 15 Inspex II SFTP...

Страница 3: ...age Editor 24 Save Merged Overlay Image 24 Measurement Annotation 25 Measurement Settings Fig 14 25 Grid Settings 26 System Setup for Measurement 27 Image Stacking 28 Measurement Accuracy 31 Magnifica...

Страница 4: ...removes the need for time consuming zoom change re calibrations Its unique ability to stay in calibration over the entire zoom range is one of the many features that differentiate the INSPEX II from o...

Страница 5: ...rol of the full application suite Camera control functions Auto and manual focus exposure gain brightness and white balance customization ensure ultra sharp high contrast imaging Illumination Options...

Страница 6: ...INSPEX II Quadrant Controllable Ring Light attached Lens 5 attached Mouse Mouse Mat Keyboard Power Supply HDMI to HDMI Cable Mini USB Cable USB Memory Stick Grounding Cable Arm Brackets Arm Receiver...

Страница 7: ...to system functions Improves and tailor s user access Removes the risk of any accidental system movement throughout your process Ideal for Quality Control Production environments Diffused LED Dome Li...

Страница 8: ...t and ground the ESD cable to bench Route the HDMI cable to the monitor Insert the mouse dongle and keyboard dongle into the side ports on the INSPEX II Note The mouse dongle must be plugged in before...

Страница 9: ...er up the unit 2 Place the unit in Overview Mode by selecting the Overview tab in the menu bar 3 Move the object until the desired viewing area is under the crosshair of the screen 4 Exit Overview mod...

Страница 10: ...II toolbar icons Fig 3 Zoom in Zoom out Toggle between live and static image Take snapshot of a live image Auto Focus Camera Overview Settings Save File Open File Overlay Measurement Image Stacking L...

Страница 11: ...nd measurement tools deactivate suitable for inspection only Overview To capture an image from a Live video feed click on the Snapshot icon A still image from the camera is captured and displayed To s...

Страница 12: ...s enabled Gain Iris and Shutter adjustments are disabled and automatically adjusted The values for these disabled settings are not relevant when auto exposure is set active Focus Switch between Auto M...

Страница 13: ...connected the quadrant buttons are disabled Settings System Settings Lens Diopter Choose a lens from the drop down list to correspond with the lens that is fitted to the INSPEX II Screen Size Enter th...

Страница 14: ...to Shutdown Timer to automatically shut down the system at a specific time to save energy This feature allows the user to set a shutdown time after start up Once the user has set the specific time and...

Страница 15: ...updated with the changes Inspex II SFTP Network connection The Inspex II supports SFTP Secure File Transfer Protocol allowing all files to be accessed from the Inspex II as a Read Only Drive Any oper...

Страница 16: ...be manually restarted to reconnect Soft Mount If the server connection is lost while navigating the NFS directory the system will not stall but data corruption may occur Click Connect The Inspex II wi...

Страница 17: ...ogin at startup This will enable the Login Log off feature There is only one superuser and this user cannot be deleted It is important to take note of the Superuser password if it is changed or before...

Страница 18: ...Inspex II User Manual 18 P a g e INSPEX II English Rev 1 06 SW Rev 1 06 Users Continued Fig 8a User details...

Страница 19: ...hould be installed individually for System Software and ringlight firmware Fig 9 Upgrade files if available can be obtained from Ash Upgrades are included in your standard warranty which is valid one...

Страница 20: ...tached NB Please note or screenshot this detail if system update or troubleshooting is required Disk Space Disk space displays the total available and used space on the system System Time Click the Ed...

Страница 21: ...urement A measurement file is saved as a ash format Ash Technologies specific format When the file is reopened on the INSPEX II as a measurement the measurements can then be edited They cannot be edit...

Страница 22: ...nd jpg are standard image formats and can be opened on any computer Open File To open an image bmp jpg or a measurement file ash click on the open file icon Files can be accessed here from internal or...

Страница 23: ...ose Save As Ash File To open and use this newly created file click on the Overlay icon When opening this file the INSPEX II will recall any dimensions shapes or text that was saved It will also load t...

Страница 24: ...asurement and overlay files Copy the file to a USB memory stick Insert the USB Key into the INSPEX II and click on the Overlay icon Select USB Key from the Look In drop down menu on the INSPEX II syst...

Страница 25: ...13 1 Open Measurement Settings 2 Selection tool 3 Restore view restore snapshot zoom 4 Draw lines 5 Draw lines with dimensions 6 Add Text Edit Text Object colour 7 Line width 8 Grid on off 9 Delete it...

Страница 26: ...t to inches or mm the grid will have a spacing of 1mm or 1 inch Grid Line Width Pixel width of the line Grid Colour Set the grid line colour Grid Type Lines or dots A measurement contains the System S...

Страница 27: ...t of the object or the height of the INSPEX II You can now zoom out from full magnification via zoom out icon until the area you wish to measure can be viewed You can now zoom in and out freely to tak...

Страница 28: ...object This however does not solve the issue of having all components in focus on the one image at the same time To do this you can use the Image Stacking function Note When processed the stacked imag...

Страница 29: ...on the stand the Omni is mounted on 3 Now A click on the Go to Top Focus button then B adjust the focus using the up down arrows in the Adjust Top Focus Section Fig 19 When this is done you can press...

Страница 30: ...ssed image will now be displayed in static form with all components heights in focus Fig 20 6 For better image quality you can increase the number of images taken in the stack and or you can increase...

Страница 31: ...w small differences when measured at different temperatures These differences are still within the specified 1 accuracy Magnification X6 X10 X25 X50 X85 X100 X125 X150 X175 X200 X250 X510 X660 5 Lens...

Страница 32: ...INSPEX II User Manual INSPEX II English Rev 1 06 SW Rev 1 06 Magnification Table Specifications obtained using a 24 Monitor Depth of Field measured with optimal image settings Fig 24...

Страница 33: ...the Overlay Graticule icon NOTE Show Preset Toolbar must be enabled when creating and saving a Preset Creating A New Preset 5 sample Presets are supplied with the unit in the Presets directory They ca...

Страница 34: ...ts HD Ready or Full HD recommended Input Output HDMI Output USB 2 0 Port x 4 RJ45 Ethernet Connector for networking General Purpose IO Port x 3 DC Power Jack 24V Image Capture Internal Image Storage R...

Страница 35: ...echnologies discretion any equipment which exhibits such defects provided that the equipment has been operated under the proper conditions of installation and has not been tampered with by any persons...

Страница 36: ...ence to use solely with the Ash Product and solely in object code form the Software Reservation of rights Except for the licence explicitly granted by Clause 0 the Licensor reserves all its rights The...

Страница 37: ...ved it directly or indirectly from the Licensor or b is or becomes generally available to the public through no act or default of the End User or its agents employees or affiliates Disclosure to emplo...

Страница 38: ...ent rates for all time costs and expenses incurred by the Licensor in consequence of such investigation No implied warranties etc The express undertakings and warranties given by the Licensor in this...

Страница 39: ...he notice if the Other Party is in material or persistent breach of any provision of this EULA and in the case of a breach capable of remedy within 30 days the breach is not remedied within 30 days of...

Страница 40: ...incorporated and unincorporated persons and references to the singular include the plural and vice versa references to Clauses and Exhibits mean clauses of and exhibits to this EULA references in thi...

Страница 41: ...nsor may directly or indirectly disclose or otherwise make available to the End User during the course of or in anticipation of this EULA Ash Product The product on which the Software is installed Sof...

Страница 42: ......

Отзывы: