![RVP 6536 SERIES Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/rvp/6536-series/6536-series_service-manual_1503350009.webp)
9
EXTERNAL STATIC
PRESSURE (INCHES OF
WATER COLUMN)
SCFM
SCFM
EXTERNAL STATIC
PRESSURE (INCHES OF
WATER COLUMN)
AMPS
AMPS
0 .1 .2 .3 .4 .5 .6 .7 .8
543 543 543 538 532 505 476 439 384
2.07 1.96 1.88 1.78 1.66 1.55 1.47 1.35 1.26
0 .1 .2 .3 .4 .5 .6 .7 .8
779 753 714 686 648 602 563 527 458
2.86 2.71 2.63 2.53 2.41 2.31 2.22 2.14 2.00
8. PACKAGED AIR CONDITIONER BLOWER
PERFORMANCE DATA
TEST CONDITION: 115 VAC, 60 HZ, 1 PHASE, DRY COIL
CHART 1
9. INDOOR BLOWER MOTOR
REMOVAL
1.
Remove indoor blower access panel.
2.
Disconnect wiring from motor terminal block and
capacitor.
3.
Remove 4 screws from venturi (See #1, Figure 7).
4.
Remove 3 screws from motor mount bracket
(See #2, Figure 7).
5.
Remove motor assembly from scroll.
6.
Remove blower wheel and motor mounting bracket.
Note:
Upon reassembly, the references made on
Figures 7 and 8 shall be used for proper
reassembly.