30
Green L.E.D. Light
Refer To Checkout. No
Green L.E.D. Light,
Heat Mode
NO
Thermostat Call
Indoor Blower
High Fan
Compressors
5 Second Delay On Make
Energizes 1st & 2nd Stage
Reversing Valves
Refer To I.D.
Blower Checkout
Heat Mode
N
O
N
O
Compressor #1
N
O
Refer To O.D. Blower
Low Checkout
Refer To Reversing
Valve Checkout
Refer To Compressor #1
Checkout Heat Mode
30 Second Delay On Make And
Compressor #2 Is Energized
*
*
O.D. Blower
Low Speed
2 Second Delay
O.D. Blower Low
L.E.D. Light
O.D. Blower High L.E.D.
O.D. Blower High Speed
Refer To O.D. Blower
High Checkout
N
O
NO
Refer To Compressor #2
Checkout Heat Mode
N
O
N
O
N
O
B. 6536 SERIES OPERATION SEQUENCE
HEATING MODE