15
1
6
2
4
14
16
13
17
7
15
11
12
9 x2
5
10
8 x2
12. INDOOR COIL REPLACEMENT
1.
Refer to Outdoor Coil Replacement (Steps 1
through 7).
2.
Remove screws from bottom of step panel (See #6,
Figure 12).
3.
Remove freeze thermister located on indoor blower
side of evaporator coil (pull top of indoor blower
assembly outward if necessary).
4.
Pull step panel slightly off to one side.
5.
Unbraze refrigerant from points (See #1 and #5,
Figure 12). Protect wiring and insulation from torch
flame.
6.
Remove screws (See #7, #8 & #9, Figure 12).
Evaporator coil can now be removed.
Note:
Upon reassembly, the references made on
Figures 11 and 12 shall be used for proper
reassembly. The assemblies shall be
secured with wire ties in order to prevent
excess chafing and vibration. If additional
sealant is needed to seal coil header to drain
pan (notched end), a silicone or perma-gum
sealant is adequate. Do not use solvent base
sealers that would harm the ABS plastic
drain pan.